MTP SW6 • Remote Contol
Remote Control, cont’d
3-6
MTP SW6 • Remote Contol
3-7
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Input selection
N The switcher supports 1-, 2-, and 3-digit numeric entries (1!, 02&, or 003%). The switcher reports all selections with 1-digit numbers.
N The & select and the % select commands for video can be used interchangeably.
Select input X! to
output, video and audio
X!!AllX!] Select input X! video and audio to be the output.
Example: 1! All1]Select input 1 video and audio.
Select input X! to
output, video only
X!&VidX!] Select X! video (audio breakaway).
Example
(see 2nd Note, above):
5& Vid5]Select input 5 video.
Select input X! to
output, video only
X!% VidX!] Select X! video (audio breakaway).
Tie input X! to output,
audio only
X!$AudX!] Select X! audio (audio breakaway).
Example: 2$ Aud2]Select input 2 audio.
Command/response table for SIS commands
N X! = Input number
1 – 6
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Level adjustment
Set a level setting EX!*X@ILVL}IlvlX!*X@] Set level setting to X@.
Increment level
adjustment
EX!+ILVL}IlvlX!*X@] Increase the level setting.
Decrement level
adjustment
EX!
ILVL}IlvlX!*X@] Decrease the level setting.
Show level EX!ILVL} X@]
Peaking adjustment
Set a peaking setting EX!*X#IPEK}IpekX!*X#] Set peaking setting to X#.
Increment peaking
adjustment
EX!+IPEK}IpekX!*X#] Shift the image one pixel to the right.
Decrement peaking
adjustment
EX!
IPEK}IpekX!*X#] Shift the image one pixel to the left.
Show peaking EX!IPEK} X#]
N X! = Input number
1 – 6
X@ = Input level range 00 – 255
X# = Input peaking range 0
– 65