3-

Command/response table for SIS commands

 

6

 

 

 

 

 

 

 

 

 

 

 

Command

ASCII Command

Response

Additional description

MTP

 

(host to unit)

 

(unit to host)

 

Input selection

 

 

 

 

 

 

 

 

 

SW6

N The switcher supports 1-, 2-, and 3-digit numeric entries (1!, 02&, or 003%). The switcher reports all selections with 1-digit numbers.

N The & select and the % select commands for video can be used interchangeably.

Select input X!to

X!!

 

AllX!]

Select input X!video and audio to be the output.

Remote

 

output, video and audio

 

 

 

 

 

 

 

 

 

 

Example:

1!

 

All1]

Select input 1 video and audio.

Control

Select input X!to

X!&

 

VidX!]

Select X!video (audio breakaway).

(see 2nd Note, above):

 

 

 

 

 

output, video only

 

 

 

 

 

Example

5&

 

Vid5]

Select input 5 video.

 

Select input X!to

X!%

 

VidX!]

Select X!video (audio breakaway).

 

output, video only

 

 

 

 

 

Tie input X!to output,

X!$

 

AudX!]

Select X!audio (audio breakaway).

 

audio only

 

 

 

 

 

Example:

2$

 

Aud2]

Select input 2 audio.

 

 

 

 

 

 

N X!= Input number

1 – 6

 

 

Command/response table for SIS commands (continued)

 

Command

ASCII Command

Response

Additional description

 

 

(host to unit)

 

(unit to host)

 

 

Level adjustment

 

 

 

 

 

Set a level setting

EX!*X@ILVL}

 

IlvlX!*X@]

Set level setting to X@.

 

Increment level

EX!+ILVL}

 

IlvlX!*X@]

Increase the level setting.

 

adjustment

 

 

 

 

 

Decrement level

EX!ILVL}

 

IlvlX!*X@]

Decrease the level setting.

 

adjustment

 

 

 

 

 

Show level

EX!ILVL}

 

X@]

 

 

Peaking adjustment

 

 

 

 

 

Set a peaking setting

EX!*X#IPEK}

IpekX!*X#]

Set peaking setting to X#.

MTP

Increment peaking

EX!+IPEK}

 

IpekX!*X#]

Shift the image one pixel to the right.

adjustment

 

 

 

 

 

 

 

 

 

SW6

Decrement peaking

EX!IPEK}

 

IpekX!*X#]

Shift the image one pixel to the left.

adjustment

 

 

 

 

Show peaking

EX!IPEK}

 

X#]

 

 

 

 

 

 

Remote

X#= Input peaking range

0 – 65

 

 

 

N X!= Input number

1 – 6

 

 

 

X@= Input level range

00 – 255

 

Control

 

 

 

 

 

3-7

 

 

 

 

 

Remote Control, cont’d

Page 21
Image 21