To install and set up an SCP 150, SCP 150 AAP, or SCP 150L, follow these steps:

1Turn the equipment off. Make sure that the SCP and the System 5 IP switcher are disconnected from the power source.

2Run cables through the wall or furniture where the SCP will be installed.

3Prepare the site and install and ground the electrical box, surface mount box, or mounting brackets.

4Set the panel address DIP switch on the back of the SCP.

5Wire the 5-pole captive screw connectors on both ends of the cable that was installed in the wall or furniture in step

2.

6Plug the wired connectors into the CM/IR/SCP connectors on the back of the SCP and on the rear panel of the switcher.

7Restore power to the switcher.

8Press an input selection button. If the corresponding LED does not light or the switch to the selected input is not made, disconnect power from the switcher and verify correct connector wiring at both ends of the cable.

9Mount the SCP in the electrical box, surface mount box, or mounting brackets. Make sure the faceplate is tied to an earth ground to prevent damage caused by electrostatic discharge.

3.Separate the white backing from the clear button cap: insert the blade of the small screwdriver into the corner notch and gently twist the blade.

4.Save the translucent, white backing plate, but remove the text/label insert from the transparent button cap.

5.Select one of the premade button labels from the label sheets included with the SCP. Remove the label from its backing and peel the protective film from the front of the label, if applicable.

You may also use a Brother P-Touch label maker to create custom labels. Cut the labels so they are square, 1/2 inch on each side.

6.Insert the button label into the clear button cap, align the white backing plate with the cap and firmly snap it into place.

7.Gently but firmly press the reassembled button into place in the panel.

8.Repeat steps 1 to 7 as needed to relabel other buttons.

Use notch to remove button.

Clear Button

Cap

Align tabs and lock in place.

Installing or Replacing Button Labels

You may wish to customize the SCP’s button labels. The labels can be changed at any time, but it is convenient to change them before you mount the panel. Follow these steps to change the translucent button labels:

1.Remove the button from the panel: use a small, flat bladed screwdriver such as an Extron Tweeker to gently pry a button out from the panel.

2.Locate the notch in the corner of one side of the clear outer layer.

White Backing Plate

Separate two piece button here.

Mounting Options

Mount the SCP 150 or SCP 150 AAP in an electrical box or surface mount box or use a mounting bracket to secure it to a wall, podium, table, or other furniture.

Electrical boxes can be attached to wall studs or to furniture. Use an electrical box deep enough to contain the SCP’s electrical components and the connected cables.

2-2

SCP 150 • Installation and Operation

SCP 150 • Installation and Operation

2-3

Page 6
Image 6
Extron electronic SCP 150L Installation and Operation, Installation Overview, Installing or Replacing Button Labels

SCP 150L specifications

The Extron Electronics SCP 150L is a versatile and sophisticated control processor designed to streamline AV system management in a variety of environments, including classrooms, conference rooms, and auditoriums. With a focus on ease of use and reliable performance, the SCP 150L represents an integral part of modern AV control solutions.

One of the key features of the SCP 150L is its powerful processing capability. This control processor supports a variety of interfaces and communication protocols, making it easy to integrate with existing AV systems. It is equipped with support for both serial and Ethernet communication, allowing it to control a wide range of devices, including projectors, displays, and audio systems. The SCP 150L can also manage third-party devices, providing users with expanded control options.

Another significant characteristic of the SCP 150L is its user-friendly interface. The device features an intuitive web-based interface, enabling users to configure settings, monitor system status, and execute commands from any device with a web browser. This simplicity in design ensures that users can quickly familiarize themselves with the system, reducing the learning curve associated with more complex control environments.

The SCP 150L is also designed with flexibility in mind. It supports customizable control options, allowing for tailored control schemes that can cater to specific user needs and preferences. This adaptability makes it an ideal choice for environments where AV system requirements may frequently change.

Furthermore, the SCP 150L includes support for Extron’s GlobalViewer Enterprise, which facilitates remote monitoring and management of AV systems. This feature enhances operational efficiency by allowing users to diagnose issues remotely and receive alerts, ultimately minimizing downtime and optimizing system performance.

The compact design of the SCP 150L is another notable characteristic, making it suitable for installation in a variety of settings without occupying excessive space. Its robustness ensures durability, providing users with a reliable solution that can withstand the demands of daily AV operations.

In summary, the Extron SCP 150L is a key component in effective AV system management. Its powerful processing capabilities, user-friendly interface, flexibility, and remote management support make it a standout choice for anyone seeking to enhance the functionality of their AV systems while ensuring maximum ease of use. With the SCP 150L, users can achieve a streamlined and efficient control experience that meets the dynamic needs of modern AV environments.