Remote Control

Contact Closure/Tally Out Control

The contact closure/tally out port provides a way to remotely select an input to the switcher or access feedback.

Contact closure

To select a different input number (Input 1 or Input 2) using a contact closure device, momentarily short the pin for the desired input number to logic ground (pin 3). To force one of the inputs to be always selected, leave the short to logic ground in place. The short overrides front panel input selections.

The contact closure pin assignments are shown in the table on page 2-6.

Tally out

Pins 4 and 5 provide feedback to a control system. This feedback can be accessed from a MediaLink controller or similar remote system.

Pin output

Input 1

Input 2

voltage

selected

selected

 

 

 

3

GND

GND

4

5V

0V

5

0V

5V

 

 

 

Figure 3-1 — Active voltages for pins 4 and 5

SW2 VGAcc and SW2 RBGHVcc

AAppendix A

Reference Information

Specifications

Switchers

Included Parts

Cables

Accessories

4-2 SW2 VGAcc and SW2 RGBHVcc • Remote Control

Page 13
Image 13
Extron electronic SW2 VGACC AAppendix a, Reference Information, Remote Control Contact Closure/Tally Out Control