Introduction, cont’d
TPS150 Switching and Transmission System • Introduction1-4

Transmission distance

The maximum distance is determined by the output frequency and resolution. The
following table specifies the recommended maximum transmission distances using
STP or FTP CAT 5 cable, terminated with CAT 5 rated connectors.
It is possible to exceed the recommended distance; however, image quality may
be reduced.
We recommend the use of pre-terminated and tested cables. Cables terminated
on site should be tested before use.
Recommended transmission ranges at 60 Hz
Video format Maximum range
640 x 480 500 feet
800 x 600 500 feet
1024 x 768 500 feet
1280 x 1024 300 feet
1600 x 1200 250 feet

Features

Four input A/V switcher — Accepts, switches, and transmits RGBHV, component
video (Y, R-Y, B-Y), S-video, composite video, and RS-232 serial content.
Accepts and switches unbalanced line level stereo audio.
Buffered monitor output on input 1 — Provides for local monitor output on a
15-pin HD female VGA connector, enabling a signal to be easily monitored
locally without the need for a separate distribution amplifier.
Universal projector control — The TPS150 provides universal projector control via
serial commands entered by the installing technician. Commands are
automatically sent when the input selection or Projector Power buttons are
pressed. The included ICS100 control software makes storing projector or
display control codes easy
Skew compensation control — Individual red, green, and blue skew controls
adjust for the timing delays commonly encountered when CAT 5, CAT 5e, or
CAT 6 cable is used.
Sharpness control — Provides video equalization with individual low frequency
and high frequency adjustments. The low frequency control helps remove
image smearing. The high frequency control restores image sharpness and
detail.
Audio input level adjustment — Each individual input has a level adjustment via
the front panel and RS-232 control. Audio levels are saved for each input and
are automatically recalled when that input is selected.
Audio output volume adjustment and muting — The output has volume control
adjustment via the front panel, RS-232 control, or optional contact closure
panel control.
Control — Switcher control is available through the front panel, an RS-232 port
serial link, and an optional contact closure control panel. Serial control is
provided with the Extron ICS 100 control software and/or a control system
issuing serial commands.