Pressure Testing

Cooktop & Installation Manual

Model COGB ENGLISH

Pressure Testing

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).

This appliance, as well as its individual shut-off valve, must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 PSIG (3.5 kPa). When checking appliance regulator function, make certain pressure of natural gas supply is between 6 and 14 inches of water column or, if converted for LP gas, between 11 and 14 inches.

THE PRESSURE TESTING SHOULD BE

PERFORMED BY MEANS OF THE INJECTOR

THREAD ZONE

Gas test inlet

014

Thread

 

Figure 14.

Pressure Test Method

Remove grate and burner cap

Remove aluminum gas spreader

Temporarily remove the injectors

Connect the pressure Test instrument into injector holder thread zone (M6x0,75)

Check if the cooktop has the correct pressure

Fix the injector removed for testing and replace the parts in the right position.