| Cooktop & Installation Manual | |||
| Model COGB | ENGLISH | ||
ALTERNATIVE PIPING METHODS TO CONNECT |
|
|
| |
APPLIANCE TO GAS SUPPLY A TRAINED |
|
|
| |
SERVICE MAN OR GAS APPLIANCE INSTALLER |
|
|
| |
MUST MAKE THE GAS SUPPLYCONNECTION. |
|
|
| |
Leak testing of the appliance shall be conducted |
| MANIFOLD |
| |
by the Installer according to the Instructions |
| ENTRANCE | ||
|
|
| ||
given. |
|
| FLARE | |
Unless prohibited by local codes or ordinances, a new |
|
| UNION | |
GASKET | GASKET | ADAPTOR | ||
A.G.A. - Certified, flexible metal appliance connector |
| |||
may be used to connect this appliance to its gas | FLARE UNION | 1/2" NPT |
| |
supply. The connector must have an internal diameter | ADAPTOR |
| ||
APPLIANCE | PIPE NIPPLE |
| ||
not less than nominal 1/2” NPT pipe and be no more | ELBOW |
| ||
PRESSURE |
|
| ||
than 5 feet in length. A 1/2” NPT x 1/2” flare union | REGULATOR, | FLEXIBLE | ||
adapter is required at each end of the flexible | SUPPLIED (OBSERVE | APPLIANCE | ||
DIRECTIONALITY | CONNECTOR | |||
connector. | OF GAS FLOW) | (5 FT.) MAX | ||
If a flexible connector is used assure that both the | FLARE | (1.52 m) MAX | ||
appliance pressure regulator and manual | UNION |
| FLARE | |
valve are joined solidly to other permanent hard piping | ADAPTOR |
| UNION | |
(either gas supply or the appliance manifold) so as to | FLEXIBLE | ADAPTOR | ||
APPLIANCE | ||||
be physically stationary. See figure 13. | APPLIANCE | |||
PRESSURE REGULATOR, | ||||
| CONNECTOR | SUPPLIED (OBSERVE | ||
| (5 FT.) MAX | |||
CAUTION | DIRECTIONALITY | |||
(1.52 m) MAX | ||||
OF GAS FLOW) | ||||
Do not attempt to attach the flexible connector directly |
|
|
| |
to an external pipe thread. | FLARE | 1/2" NPT | ||
Connection requires flare union adapters. | UNION | PIPE NIPPLE | ||
| ADAPTOR |
|
| |
For Massachusetts Installations: | GAS |
| GAS | |
1. | VALVE |
| VALVE | |
2. Flexible gas connector must not be longer than 36 | 1/2" NPT PIPE | 1/2" NPT PIPE | ||
inch. | (STATIONARY | (STATIONARY | ||
3. Not approved for installation in a bedroom or a | SUPPLY PIPE) | SUPPLY PIPE) | ||
|
|
| ||
bathroom unless unit is direct vent. | NO APPLIANCE | WALL OVEN MOUNTED | ||
| ||||
| MOUNTED BELOW | IN CABINETRY BELOW | ||
| THIS COOKTOP | THIS COOKTOP | ||
|
|
| 013 | |
| Figure 13. |
|
|
12