ALTERNATIVE PIPING METHODS TO CONNECT

 

 

 

APPLIANCE TO GAS SUPPLY A TRAINED

 

 

 

SERVICE MAN OR GAS APPLIANCE INSTALLER

 

 

 

MUST MAKE THE GAS SUPPLYCONNECTION.

 

 

 

Leak testing of the appliance shall be conducted

 

MANIFOLD

 

by the Installer according to the Instructions

 

ENTRANCE

 

 

 

given.

 

 

FLARE

Unless prohibited by local codes or ordinances, a new

 

 

UNION

GASKET

GASKET

ADAPTOR

A.G.A. - Certified, flexible metal appliance connector

 

may be used to connect this appliance to its gas

FLARE UNION

1/2" NPT

 

supply. The connector must have an internal diameter

ADAPTOR

 

APPLIANCE

PIPE NIPPLE

 

not less than nominal 1/2” NPT pipe and be no more

ELBOW

 

PRESSURE

 

 

than 5 feet in length. A 1/2” NPT x 1/2” flare union

REGULATOR,

FLEXIBLE

adapter is required at each end of the flexible

SUPPLIED (OBSERVE

APPLIANCE

DIRECTIONALITY

CONNECTOR

connector.

OF GAS FLOW)

(5 FT.) MAX

If a flexible connector is used assure that both the

FLARE

(1.52 m) MAX

appliance pressure regulator and manual shut-off

UNION

 

FLARE

valve are joined solidly to other permanent hard piping

ADAPTOR

 

UNION

(either gas supply or the appliance manifold) so as to

FLEXIBLE

ADAPTOR

APPLIANCE

be physically stationary. See figure 13.

APPLIANCE

PRESSURE REGULATOR,

 

CONNECTOR

SUPPLIED (OBSERVE

 

(5 FT.) MAX

CAUTION

DIRECTIONALITY

(1.52 m) MAX

OF GAS FLOW)

Do not attempt to attach the flexible connector directly

 

 

 

to an external pipe thread.

FLARE

1/2" NPT

Connection requires flare union adapters.

UNION

PIPE NIPPLE

 

ADAPTOR

 

 

For Massachusetts Installations:

GAS

 

GAS

SHUT-OFF

SHUT-OFF

1. Shut-off valve must be a "T" handle gas cock.

VALVE

 

VALVE

2. Flexible gas connector must not be longer than 36

1/2" NPT PIPE

1/2" NPT PIPE

inch.

(STATIONARY

(STATIONARY

3. Not approved for installation in a bedroom or a

SUPPLY PIPE)

SUPPLY PIPE)

 

 

 

bathroom unless unit is direct vent.