16

G-DEC 3O

G–DEC 30 MIDI Configuration

In Utility Mode you can set MIDI CONTROL (menu 9) to SYNTH or AMP. If set to AMP, data sent on MIDI channel 16 will control the amp, and channels 1-15 will be routed to the synth. This will present a problem if a normal MIDI song is played with music on channel 16 (which could affect the amp settings in unexpected ways). In this case you can either delete channel 16 or move it to a different channel. If MIDI CONTROL is set to SYNTH, all MIDI data will be routed to the synth. When

songs are created in the COMPOSE Mode, program changes will be saved in the song on channel 16 regardless of the MIDI Amp Control setting, but the program changes will only work during playback if the amp is set to AMP. MIDI on channel 16 is also passed from the MIDI input jack to the DSP during playback of songs or patterns if the MIDI CONTROL is set to AMP.

GDEC30 MIDI Controls

If the MIDI CONTROL is set to AMP the following commands can be used (on CH 16).

Amp Control

Control Type

Value Range

Preset Num

Program Change

0-99,127=Tuner

Amp Volume

CC#07

0-127

Synth Volume

CC#11

0-127

Start/Stop MIDI

CC#85

Don’t care

Play

CC#86

Don’t care (Ignored if the

 

 

amp is busy playing a

 

 

pattern or song)

Record

CC#87

Don’t care (Ignored if the

 

 

amp is busy playing a

 

 

pattern or song)

Overdub

CC#88

Don’t care (Ignored if the

 

 

amp is busy playing a

 

 

pattern or song)

Data Increment

CC#96

Don’t care

Data Decrement

CC#97

Don’t care

Amp Gain

CC#102

0-127

RVB Level

CC#108

0-127

FX Level

CC#110

0-127

FX Param1

CC#111

0-127

FX Param2

CC#112

0-127

FX Param3

CC#113

0-127

FX Param4

CC#114

0-127

Select Song

CC#119

0-63 (Ignored if the amp

 

 

is busy playing a pattern

 

 

or song)

fender.com

Page 16
Image 16
Fender G-DEC 30 manual DEC 30 Midi Configuration, GDEC30 Midi Controls, Amp Control