FieldServer FCI 7100 Series Serial Driver Description, Page 3 of, Max Nodes Supported

Models: FCI 7100 Series FS-8700-112

1 24
Download 24 pages 19.37 Kb
Page 3
Image 3
FS-8700-112 FCI 7100 Series Driver Manual

FS-8700-112 FCI 7100 Series Driver Manual

Page 3 of 24

1.FCI 7100 Series Serial Driver Description

The FCI 7100 Series System Control Units are manufactured by Fire Control Instruments. A 7100 with an enabled serial port can transmit data to a FieldServer which can, in turn, make the data available to other devices including those which communicate using different protocols (e.g. BACnet)

This passive Client driver does not poll for data, nor does it send data or commands to the 7100. Messages received from the 7100 are ignored or stored on the FieldServer depending on the status of the panel. The method of message processing and location on the FieldServer is determined in the FieldServer configuration file. Once stored in the FieldServer the data is available to be read or written using other protocols such as BACnet.

No automatic panel data synchronization technique exists. The data in the FieldServer and the panel status have to be synchronized manually. This typically requires a panel reset.

Since the driver cannot send data or commands to the 7100 it cannot be used to acknowledge, silence or reset alarms and other events.

The driver can process the single line messages sent from 7100 firmware versions earlier than

2.20and 3 line messages produced in firmware versions 2.20 and later. Processing of 3 line messages requires the 20 character System ID label to be defined.

The driver can process messages from networked panels. The driver connects to the main panel. Subsidiary panels are configured to send event data to the main panel which then sends messages to the FieldServer. If the panel is configured to send 3 line messages then the source node information is sent in the line preceding the event and the driver uses this to determine the panel at which the event originated and to store data appropriately.

The driver provides both client and server emulation. The server side of the driver is intended to support FieldServer’s Quality Assurance program and is not intended to provide complete emulation of a 7100 and is thus not fully documented. Should you require the Server side functionality to be documented and enhanced, please contact FieldServer’s sales group.

Max Nodes Supported

 

FieldServer Mode

Nodes

 

 

Comments

 

 

 

 

 

1 Node per serial port. If there is more than one alarm

 

Client

1

 

 

panel they can be networked and configured to send event

 

 

 

data to the primary panel. The driver can process

 

 

 

 

 

 

 

 

 

 

messages which identify the node of origin.

 

Server

1

 

 

1 Node per serial port

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Page 3
Image 3
FieldServer FCI 7100 Series Serial Driver Description, FS-8700-112 FCI 7100 Series Driver Manual, Page 3 of, Nodes