FS-8700-112 FCI 7100 Series Driver ManualPage 19 of 24

Appendix B. Driver Error Messages.

Message

 

 

 

 

 

Description

 

FCI7100:#1 FYI. Use a DA called <%s> to expose

Refer to Appendix B.1

diagnostic info., FCI_7100_STATS_DA )

 

 

 

FCI7100:#2

FYI. Added

Event

Desc=<%s>

 

 

Index=%d

Categ=%d

,

new_event_desc

,

Printed for your info only. No action

new_event_desc_index_value

 

,

required if it confirms your expectations.

new_event_desc_categ ) ;

 

 

 

 

 

FCI7100:#3

Err. No space. Reject Event

There is only space for 60 event types.2

Desc=<%s> Index=%d , new_event_desc

,

new_event_desc_index_value ) ;

 

 

 

 

 

 

 

 

 

 

You are adding an event type that

FCI7100:#4 FYI. Duplicate Event Desc=<%s>. ,

already exists.

If you are updating the

new_event_desc ) ;

 

 

 

 

category, ignore the message. Otherwise

 

 

 

 

 

 

correct the configuration file.2

 

 

 

 

 

 

You are adding an event type that

FCI7100:#5 FYI. Duplicate Event Desc=<%s>. ,

already exists.

If you are updating the

new_event_desc ) ;

 

 

 

 

index value, ignore the message.

 

 

 

 

 

 

Otherwise correct the configuration file.2

FCI7100:#6 Err. Event Index=%d. Too big to set

If the event index is greater than 64 then

the data cannot be stored as bits as only

bit., drv_bd->event_index )

 

 

 

64 bits are reserved for events.

 

 

 

 

 

 

FCI7100:#7a Err. DA=%s too short. Rqd=%d, dt-

The MD in question has a length and

>buffer_name , offset );

 

 

 

 

offset which makes it run past the end of

FCI7100:#7b Err. DA=%s too short. Rqd=%d,

the Data Array. Message 7b is printed

possible_md->data->buffer_name , offset );

 

when data is being stored as bits.2

FCI7100:#8 FYI. Reset was rcvd and processed!

Printed for your info only. No action

Stamped %s %s , drv_bd->time , drv_bd->date )

 

required.

 

 

 

 

 

 

 

This message is printed when a reset

FCI7100:#9 Err. Reset was ignored.

 

 

was received but for one or more reason

 

 

the driver could not reset any data. Have

 

 

 

 

 

 

you set 'Clear_on_Reset' to 'no' on all

 

 

 

 

 

 

MD's ?

 

FCI7100:#10 FYI. Reset of DA=%s Off=%d

 

 

Len=%d, possible_md->data->buffer_name ,

Printed for your info only. No action

possible_md->bxi_data_buffer_offset

 

,

required..

 

possible_md->data_length );

 

 

 

 

 

FCI7100:#11 Err. Cant reset DA=%s len=%d

 

 

rqd=%d,

possible_md->data->buffer_name

,

The MD in question has a length and

da_get_length_in_items

 

(

(DAH_TYP)

offset which makes it run past the end of

possible_md->data

)

,

possible_md-

the Data Array.2

 

>data_length+possible_md-

 

 

 

 

 

>bxi_data_buffer_offset );

 

 

 

 

 

2Correct the configuration file, download to the FieldServer and restart the FieldServer for the changes to take effect.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Page 19
Image 19
FieldServer Appendix B. Driver Error Messages, FS-8700-112 FCI 7100 Series Driver ManualPage 19, Message Description