FS-8700-41 Simplex Driver Manual

Table of Contents

 

TABLE OF CONTENTS

 

1.

Simplex Time Recorder Company - 4100 Computer Port Protocol

............................. 4

1.1.

SupportedPanelTypes

................................................................. 4

1.2.

SimplexPanelFirmwareRevisionvs.SupportedFunct

ionality

4

2.

Driver Scope of Supply

 

5

2.1.

SuppliedbyFieldServerTechnologiesforthisdrive

r

5

2.2.

ProvidedbySupplierof3 rdPartyEquipment

...................................

............................ 5

3.

Hardware Connections

 

6

3.1.

ConnectiontoaSimplex4020Panel

.......................................................... 7

3.2.

ConnectiontoaSimplex4100Panel

.......................................................... 9

3.3.

ConnectiontoaSimplex4100UPanel

.......................................................10

4.Configuring the FieldServer as a Simplex Time Recorder Company - 4100 Computer

 

Port Protocol Client

12

4.1.

DataArrays

12

4.2.

ClientSideConnectionDescriptions

..........................................................13

4.3.

ClientSideNodeDescriptors

..............................................................13

4.4.

ClientSideDriverTables

..................................................................14

4.4.1. SHOW Response Attributes Driver Table

14

4.4.2. SHOW Response Attribute States Driver Table

15

4.5.

ClientSideMapDescriptors

...............................................................15

4.5.1. FieldServer Specific Map Descriptor Parameters

15

4.5.2. Driver Specific Map Descriptor Parameters

15

4.5.3. Timing Parameters

15

4.5.4. Protocol (Simplex Device) Specific Parameters

16

4.5.5. Map Descriptor Example 1. - Read Point Status

17

4.5.6.Map Descriptor Example 2. - Use unsolicited messages from the Panel to

determine point status

18

5.Configuring the FieldServer as a Simplex Time Recorder Company - 4100 Computer

Port Protocol Server

 

19

Appendix A.

Advanced Topics

 

20

AppendixA.1.

HardwareHandshaking

 

20

AppendixA.2.

SimplexAddressFormatting–SpecificKeywords

.....

..................................20

Appendix A.2.1.

Sim4100_Card Keyword

 

24

Appendix A.2.2.

<apoint>

 

24

Appendix A.2.3.

Sim4100_Point Keyword

 

24

Appendix A.2.4.

Sim4100_sub Keyword

 

24

AppendixA.3.

HowtouseDataArraystomapto/fromCardPointSu

baddresses

25

AppendixA.4.

SimplexPointStatusDataFormat

............................................25

AppendixA.5.

SimulationoftheXpointcommand

............................................26

AppendixA.6.

ApplicationSupervisionMessages

............................................26

AppendixA.7.

DriverStats

 

26

Appendix A.7.1. How the Driver counts bytes and messages received and transmitted...

26

Appendix A.7.2. Driver Exposed Stats

 

27

AppendixA.8.

SHOWFunctionAttributesandAttributeStates

.....................................28

Appendix A.8.1. Extending the List of Show Attributes

 

31

AppendixA.9.

SynchronizingtheFieldServerwiththePanel

.......................................31

AppendixA.10. AdvancedMapDescriptorExample1Errors

...................................33

FieldServer Technologies1991TarobCourtMilpitas,California95035USA

Web:www.fieldserver.com

Tel:(408)2622299

Fax:(408)2622296

Toll_Free:8885091970

email:support@fieldserver.com

Page 2
Image 2
FieldServer FS-8700-41 instruction manual Table of Contents

FS-8700-41 specifications

The FieldServer FS-8700-41 is an advanced data acquisition and control device designed for a variety of industrial automation applications. Known for its versatility and reliability, the FS-8700-41 serves as a critical component in enhancing communication between disparate devices and systems within HVAC, energy management, and water treatment sectors.

One of the main features of the FS-8700-41 is its ability to interface with multiple protocols simultaneously. The device supports a wide range of communication protocols, including Modbus, BACnet, Johnson Controls N2, and many others. This multi-protocol support allows for seamless integration in diverse environments where different devices may be using different communication standards.

The FS-8700-41 is equipped with robust hardware specifications that ensure high-performance data processing and collection. It features a powerful processor capable of handling complex data operations while maintaining a user-friendly interface. The device also has multiple input/output configurations, allowing for flexible deployment in various operational scenarios.

Security is another paramount characteristic of the FS-8700-41. With built-in encryption and secure authentication protocols, the device helps to protect sensitive data from unauthorized access and cyber threats. This feature is particularly important in industries focused on critical infrastructure and sensitive operational data.

In terms of connectivity, the FS-8700-41 offers both wired and wireless options, giving users the freedom to implement the device into their existing systems with ease. The inclusion of Ethernet connectivity and support for wireless communication protocols allows for easy integration into cloud-based platforms for real-time monitoring and data analysis.

Additionally, the FS-8700-41 provides extensive diagnostic and troubleshooting capabilities. Users can access comprehensive logging and reporting tools that help identify issues quickly, minimizing downtime and enhancing operational efficiency.

Furthermore, the FS-8700-41 is designed with a rugged housing to withstand harsh industrial environments, making it suitable for installation in a variety of settings, from factories to outdoor applications. Its ease of installation and configuration significantly reduces setup time, allowing for rapid deployment.

Overall, the FieldServer FS-8700-41 stands out as a powerful solution for integrating various technologies in a cohesive manner, making it a preferred choice for professionals seeking reliable data communication solutions in industrial environments.