FS-8700-41 Simplex 4100 Driver Manual

 

Page 45 of 58

 

 

 

 

 

 

 

 

 

Error Message

 

 

Troubleshooting Tip

 

 

 

 

 

 

Awritethruisdefinedasfollows.TheFieldServer

 

 

 

 

 

 

 

reads data from a device and stores it in a Data

 

 

 

 

 

 

Array.Ifaremotedevicechangesthevalueintha

t

 

 

 

 

 

 

DataArray,theFieldServerwillwritethenewvalu

e

 

 

 

 

 

 

tothedevicethatisbeingread. Thisdriverdoes

 

 

 

Sim4100:#14MD=%sAddr=%d

 

not permit write thru's except when the data is

 

 

 

 

beingupdatedusingCLIST.ReferalsotoSections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.5.4,4.5.6andAppendixA.20. Inversionsofthe

 

 

 

 

 

 

 

driveruptoandincluding1.07aapanicisproduce

d

 

 

 

 

 

 

when this message is printed. The message is

 

 

 

 

 

 

 

printed to a maximum of 10 times and then

 

 

 

 

 

 

 

suppressed.

 

 

 

SIM4100:#15

FYI.

Incoming

 

Check the CSV file; there was no matching Map

 

 

 

abandoned.NoMapDesc.

 

 

Descriptorforamessage.

 

 

 

SIM4100:#16

FYI. No Map Desc.

 

Iftheservercan’tfindamatchingMD(i.e.thepo

int

 

 

 

being polled for doesn’t exist) then the driver

 

 

RespondwithError.

 

 

 

 

 

 

respondswithSimplexError#2.

 

 

 

 

 

 

 

 

 

 

SIM4100:#17

FYI.

Incoming

 

Check the driver manual and Simplex User

 

 

 

Manuals. There is no driver response to the

 

 

Abandoned.NoData.

 

 

 

 

 

 

messagereceived.

 

 

 

 

 

 

 

 

 

 

SIM4100:#18

FYI.

Incoming

 

Please report his message to FieldServer

 

Abandoned.(%d)

 

 

Technologiesnotingthevaluesinbraces.

 

 

 

 

 

 

 

Nocorrectiveactionisrequiredonyourpart. The

 

 

 

 

 

 

 

messageisprintedforyourinformationonly.

 

 

 

Sim4100:#19a FYI. Sim4100 Firmware

 

Message‘a’isprintedwhenversion9firmwareis

 

 

 

 

foundinthepanel.

 

 

 

found(%.2f)

 

 

 

 

 

 

 

 

 

Message‘b’isprintedwhenversion10firmwareis

 

 

 

 

 

 

 

 

 

 

 

 

 

 

foundinthepanel.

 

 

 

 

 

 

 

Message‘b’isprintedwhenversion11firmwareis

 

 

 

 

 

 

 

foundinthepanel.

 

 

 

 

 

 

 

The firmware version found is not one that the

 

 

 

 

 

 

 

driver explicitly supports. This does not meanthe

 

 

 

 

 

 

driverwillnotworkbutifafeatureofthedriver

isn’t

 

 

 

 

 

 

workingcorrectlyknowingthatthefirmwareversion

 

 

 

 

 

 

is not supported may help diagnose the problem

 

 

Sim4100:#19d

FYI. Panel

Firmware

 

moreeasily.

 

 

 

Rev%.2fmaybeincompatible.

 

 

 

 

 

 

 

 

 

 

No corrective action is required on your part. If

 

 

 

 

 

 

 

however, some you suspect that the driver is not

 

 

 

 

 

 

 

operatingcorrectlyitisimportantthatyoumentio

n

 

 

 

 

 

 

seeing this message in the Error Buffer when

 

 

 

 

 

 

reportingtheproblem.

 

FieldServer Technologies1991TarobCourtMilpitas,California95035USA

Web:www.fieldserver.com

Tel:(408)2622299

Fax:(408)2622296

Toll_Free:8885091970

email:support@fieldserver.com

Page 45
Image 45
FieldServer FS-8700-41 instruction manual Fyi, Incoming

FS-8700-41 specifications

The FieldServer FS-8700-41 is an advanced data acquisition and control device designed for a variety of industrial automation applications. Known for its versatility and reliability, the FS-8700-41 serves as a critical component in enhancing communication between disparate devices and systems within HVAC, energy management, and water treatment sectors.

One of the main features of the FS-8700-41 is its ability to interface with multiple protocols simultaneously. The device supports a wide range of communication protocols, including Modbus, BACnet, Johnson Controls N2, and many others. This multi-protocol support allows for seamless integration in diverse environments where different devices may be using different communication standards.

The FS-8700-41 is equipped with robust hardware specifications that ensure high-performance data processing and collection. It features a powerful processor capable of handling complex data operations while maintaining a user-friendly interface. The device also has multiple input/output configurations, allowing for flexible deployment in various operational scenarios.

Security is another paramount characteristic of the FS-8700-41. With built-in encryption and secure authentication protocols, the device helps to protect sensitive data from unauthorized access and cyber threats. This feature is particularly important in industries focused on critical infrastructure and sensitive operational data.

In terms of connectivity, the FS-8700-41 offers both wired and wireless options, giving users the freedom to implement the device into their existing systems with ease. The inclusion of Ethernet connectivity and support for wireless communication protocols allows for easy integration into cloud-based platforms for real-time monitoring and data analysis.

Additionally, the FS-8700-41 provides extensive diagnostic and troubleshooting capabilities. Users can access comprehensive logging and reporting tools that help identify issues quickly, minimizing downtime and enhancing operational efficiency.

Furthermore, the FS-8700-41 is designed with a rugged housing to withstand harsh industrial environments, making it suitable for installation in a variety of settings, from factories to outdoor applications. Its ease of installation and configuration significantly reduces setup time, allowing for rapid deployment.

Overall, the FieldServer FS-8700-41 stands out as a powerful solution for integrating various technologies in a cohesive manner, making it a preferred choice for professionals seeking reliable data communication solutions in industrial environments.