Page 28 of 29FS-8700-66_GE-SNP Manual

Page 28 of 29

 

 

 

 

 

 

 

 

Decimal

Hex

Description

 

 

 

-62

0C2

The OEM key is NULL (inactive).

 

 

 

-63

0C1

Invalid block state transition.

 

 

 

-64

0C0

Bad OMF record checksum in store.

 

 

 

-65

0BF

Illegal OMF record type/data contents.

 

 

 

-66

0B

Bad Block Type given in Load/Store.

 

 

 

-67

0BD

Block Set (subblock name) not found.

 

 

 

-68

0BC

Block Type (e.g., data) not found.

 

 

 

-69

0B

Maximum length of a partial store exceeded.

 

 

 

-70

0B

Block Set already exists, cannot create.

 

 

 

-71

0B9

Executable flag in TYPDEF record not set.

 

 

 

-72

0B8

Size of the Segment Selector Table in TYPDEF record is not correct.

 

 

-73

0B7

Segment length in Verify not equal to the segment length of block in the PLC.

 

 

-74

0B6

Cyclic Redundancy Check (CRC) checksum comparison in Verify failed.

 

 

-75

0B5

Additive checksum comparison in Verify failed.

 

 

 

-76

0B4

Attempt to alter interrupt list in MAIN DECL BLOCK during RUN MODE.

 

 

-77

0B3

Length limit exceeded; includes read past end of transferred data, writes past

 

 

 

 

ofprogram block.

 

 

 

-78

0B2

Program block already exists and cannot be replaced.

 

 

Minor Error Status Codes: Program Load and Store Requests

 

 

 

 

 

 

 

 

 

Decimal,

Hex,

Description

 

 

 

80

50

Problem with sending mail to the slave Service Request task. (Series 90-70 PLC

 

 

CPUs only).

 

 

 

 

 

 

 

 

81

51

Problem with getting mail from the slave Service Request task. (Series 90-70

 

 

PLC CPUs only).

 

 

 

 

 

 

 

 

85

55

Slave SNP task timed out before receiving SRP response. (Series 90-70 PLC

 

 

CPUs only).

 

 

 

 

 

 

 

 

86

56

Slave SNP task could not find the requested Datagram connection. (Series 90-70

 

 

PLC CPUs only).

 

 

 

 

 

 

 

 

87

57

Slave SNP task encountered an error in trying to write the Datagram. (Series 90-

 

 

70 PLC CPUs only).

 

 

 

 

 

 

 

 

88

58

Slave SNP task encountered an error in trying to update the Datagram. Series

 

 

90-70 PLC CPUs only).

 

 

 

 

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Page 28
Image 28
FieldServer 28 of 29FS-8700-66GE-SNP Manual, Minor Error Status Codes Program Load and Store Requests, 0BF, 0BD, 0BC