FieldServer FS-8700-66 GE SNP CONNECTION DIAGRAM RS-485 to RS-232 using, MODEL485OTLED, Converter

Models: FS-8700-66

1 29
Download 29 pages 60.45 Kb
Page 6
Image 6
FS-8917-01

Page 6 of 29FS-8700-66_GE-SNP Manual

Page 6 of 29

FS-8917-01

From FieldServer

2

2

 

3

3

 

 

4

5

 

7

7

J2RS- 232 TO RS-422/485OPTICALLY ISOLATED DB25F

21787

 

RS- 232 TO RS-422/485

 

 

OPTICALLY ISOLATED

RS-232

CONVERTER

422/485-SR

Transmit

 

Recceive

 

B&B electronics

MODEL485OTLED

91035

4800

9600

19.2K

38.4K

ECHO

4W/2W

4W/2W

TERM.

JP1

O

 

 

 

 

 

 

 

N

 

 

 

 

 

 

SD RTS

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

TB1

 

 

 

 

TDA(-)

 

 

 

 

 

TDB(+)

 

 

 

 

 

 

RDA(-)

 

 

 

 

 

RDB(+)

 

 

 

422/ 485 GND

 

 

 

 

 

 

+12V

 

TB2

 

 

 

 

 

 

 

 

 

 

R-232

 

 

 

 

 

 

 

GND

 

 

Remote Serial

Device– 4 wire

CONVERTERMODEL485OTLEDRemote SerialRS-232 TO RS-422/485GE SNPManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background TDA(-)

TDB (+)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background RDB(+)

RDA(-)

GND

Remote Serial

Device– 2 wire

+ (B) - (A)

GND

Converter for Cable 3: From RS-232 on FieldServer to RS-485 on device.

RS-232 Device

4800 9600 19.2K 38.4K ECHO 4W/2W 4W/2W TERM.

JP1

 

 

 

 

 

 

 

RS-232 TO RS-422/485

 

 

 

 

 

 

 

 

 

OPTICALLY ISOLATED

 

O

 

 

Rx

2

Rx

2

 

CONVERTER

 

N

 

 

 

422/485-SR

1 2 3 4 5 6 7

8

SD RTS

 

 

RS-232

GND

3

Tx

3

 

RDA(-)

 

Tx

 

 

 

Recceive

 

 

 

TB1

RTS

5

RTS

4

 

 

 

TDA(-)

 

 

 

 

 

 

 

Transmit

 

TDB(+)

 

 

 

 

 

 

 

 

 

 

 

 

GND 7

B&B electronics

422/485

 

 

 

 

RDB(+)

 

 

 

MODEL 485OTLED

GND

 

 

 

 

TB2

 

J2

 

 

7

 

+12V

 

 

 

 

 

 

 

R-232

 

 

DB25F

 

GND

FieldServer

 

Note: Pins 4&5 and pins 6,8&20 are

91035

 

 

 

 

 

R1 or R2

 

bridged internally to allow for RS-232

 

 

 

 

 

 

 

devices that need hardware control.

 

 

+ (B)

 

 

 

 

 

 

 

 

- (A)

 

 

 

 

GND

Converter for Cable 4: From RS-485 on FieldServer to RS-323 on device.

GE SNP

CONNECTION DIAGRAM

RS-485 to RS-232 using

Model4850 TLED connector.

BASE NAME:

DATE: 2/16/08

FILE NAME: FS-8700-66-1

BY: MC

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Page 6
Image 6
FieldServer FS-8700-66 GE SNP CONNECTION DIAGRAM RS-485 to RS-232 using, MODEL485OTLED, FS-8917-01 From FieldServer