Type 21 Arm-Away
Type 22
Disarm
Type 23* No Alarm Response
Type 24 Silent Burglary
Type 77 Keyswitch
Type 81 AAV Monitor Zone
Types 90-93 Installer Defined

Arms the system in Away mode when the zone is activated.

Pushbutton units send the user number to the central station when arming or disarming.

User code for button must be assigned.

Disarms the system when the zone is activated.

User code for button must be assigned.

Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g., lobby door access).

Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are NOT desired.

Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is faulted when the system is armed in the Away, Stay, Instant, or Maximum modes.

A report is sent to the central station.

Assign to zone wired to a keyswitch.

Assign to zone connected to AAV module.

Monitors 2-way voice sessions as follows:

-When the zone is faulted, all alarm sounding and dialer reporting stops, except for fire alarms, which immediately terminate the voice session and cause a fire report to be sent.

-When the zone is restored (session ended), sounding resumes (if bell timeout has not expired) and reports that were stopped are sent.

These zone types can be programmed for various custom responses. See data fields *182-*185.

Types 92 and 93 can only be programmed via the downloader.

UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations. *The system can still be armed when these zone types are in a faulted condition.

Schedules (installer code + [#] + [6] [4]; master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and events 00-07 for both controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules )

No.

Event

Device No.

Group No.

Partition

Start Time/

Stop Time/

Repeat

Random

 

(see list below)

for “01” events:

for “02” events:

for “04-06” events:

Days

Days

(1-4)

(yes/no)

 

 

enter 01-18

enter 1-8

enter 1, 2, or 3

 

 

 

 

01

 

 

 

 

 

 

 

 

02

 

 

 

 

 

 

 

 

03

 

 

 

 

 

 

 

 

04

 

 

 

 

 

 

 

 

05

 

 

 

 

 

 

 

 

06

 

 

 

 

 

 

 

 

07

 

 

 

 

 

 

 

 

08

 

 

 

 

 

 

 

 

09

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

Events:

Master/Installer

 

 

Installer Only

 

00

= clear event

04

= forced STAY arm

10 = display custom words 8-10

 

01

= device on/off

05

= forced AWAY arm

11 = periodic test report

 

02

= user access

06

= auto disarm

 

 

03

= latch key report

07

= display “reminder”

 

Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week

13

Page 13
Image 13
First Alert FA168CPS, FA148CP manual Days