ALARM RESTORE RPT CODE TROUBLE RESTORE RPT CODE BYPASS RESTORE RPT CODE AC RESTORE RPT CODE LOW BAT RESTORE RPT CODE
RF XMTR LO BAT RST RPT CODE
TEST RESTORE RPT CODE

✱65 OPEN REPORT CODE

[0,0,0] See box above.

Part. 1 Part. 2 Common

✱66

ARM AWAY/STAY RPT CODE

 

 

Away Stay

 

 

Part. 1

 

✱67

RF XMTR LOW BAT REPORT CODE

 

 

 

 

[0,0,0,0,0,0] See box above.

Away Stay

Away Stay

Part. 2

Common

[00]

See box on previous page.

UL: must be enabled if wireless devices are used

✱68 CANCEL REPORT CODE

RESTORE REPORT CODES (✱70 – ✱76) ✱70

✱71 ✱72 ✱73 ✱74 ✱75

✱76

OUTPUT AND SYSTEM SETUP (✱77 – ✱93)

✱77 DAYLIGHT SAVINGS TIME START\END MONTH

✱78 DAYLIGHT SAVINGS TIME START\END WEEKEND

∗79, *80, *81, *82 MENU MODES

 

 

[00]

 

See box on previous page.

 

 

 

See box on previous page.

 

[0]

 

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL: must be enabled if wireless devices are used

 

 

 

 

[00]

 

See box on previous page.

 

 

 

 

 

 

 

0 = Disabled

 

 

[4][10]

 

 

1-12 = January-September (1 = Jan, 2 = Feb, etc)

 

 

 

 

 

 

 

 

#+10 = October; #+11 = November; #+12 = December

 

 

 

 

0 = disabled, 1 = first, 2 = second, 3 = third

 

 

[1][5]

 

 

4 = fourth, 5 = last, 6 = next to last, 7 = third to last

 

 

 

 

These are Menu Mode commands, not data fields, for Output Device Mapping, Output Programming, Zone List Programming, and Alpha Programming respectively. See page 2 and their respective sections in the Installation and Setup Guide for procedures.

✱84 AUTO STAY ARM

✱85 CROSS ZONE TIMER

This option not for use in UL installations.

✱86 CANCEL VERIFY KEYPAD DISPLAY ✱87 MISC. FAULT DELAY TIME

(used with Configurable Zone Types “digit 6”)

[3]

[0]

(assign cross zones on zone list 4, using *81 Menu mode)

[1]

[0]

UL: may only be used on non-burglar alarm/ non-fire alarm zones when used in fire and/or UL burglar alarm installation

0 = no, 1 = partition 1 only

2 = partition 2 only, 3 = both partitions

0

= 15 seconds

6

= 2-1/2 min

#+12 = 8 min

1

= 30 seconds

7

= 3 min

#+13 = 10 min

2

= 45 seconds

8

= 4 min

#+14 = 12 min

3

= 60 seconds

9

= 5 min

#+15 = 15 min

4

= 90 seconds

#+10 = 6 min

 

5

= 2 minutes

#+11 = 7 min

 

0

= no, 1 = yes

 

 

 

0

= 15 seconds

6

= 2-1/2 min

#+12 = 8 min

1

= 30 seconds

7

= 3 min

#+13 = 10 min

2

= 45 seconds

8

= 4 min

#+14 = 12 min

3

= 60 seconds

9

= 5 min

#+15 = 15 min

4

= 90 seconds

#+10 = 6 min

 

5

= 2 minutes

#+11 = 7 min

 

✱88 PROGRAM MODE LOCKOUT OPTIONS

✱89 EVENT LOG FULL REPORT CODE ✱90 EVENT LOG ENABLES

✱91 OPTION SELECTION

[0]

[00]

[3]

NOTE: System messages are logged when any non-zero selection is made.

[8]

SIA Installations: Exit Delay should be enabled.

0 = standard *98 installer code lockout (reentry only by downloader or [∗] + [#] within 50 secs after power up)

1 = lockout [∗] + [#] reentry after *98 exit (reenter via installer code or downloader only)

2 = not used

3 = lockout all local programming after *98 exit (reentry via downloader only)

See box on previous page for report code entries.

0 = None; 1 = Alarm/Alarm Restore

2 = Trouble/Trouble Restore;

4 = Bypass/Bypass Restore;

8 = Open/Close.

Example: To select “Alarm/Alarm Restore”, and

“Open/Close”, enter 9 (1 + 8); To select all, enter #15.

0 = None

2 = Sounder Delay (delays sounding by 15 seconds) UL: if used, entry delay (*35) must be 30 sec. max.

4 = AAV UL: must use ADEMCO UVCM module

8 = Exit Delay Restart/Reset UL: must be disabled #+12 = AAV and Exit Delay Restart/Reset