First Alert FA168CPS, FA148CP manual 352*5$00,1*250

Models: FA148CP FA168CPS

1 16
Download 16 pages 23.09 Kb
Page 3
Image 3
352*5$00,1*￿)250￿￿
ALARM SOUNDER (BELL) TIMEOUT
EXIT DELAY
ENTRY DELAY #1 (zone type 01)
ENTRY DELAY #2 (zone type 02)
AUDIBLE EXIT WARNING CONFIRMATION OF ARMING DING
FIRE ALARMSOUNDER TIMEOUT

352*5$00,1*￿)250￿￿

Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP.

Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.

Field

Function

Data Entries

 

Programmable Values

SYSTEM SETUP (20–29)

 

 

 

 

 

 

 

20

INSTALLER CODE

 

 

 

 

 

4 digits, 0–9

 

 

[4112]

 

 

 

 

 

 

 

21

QUICK ARM ENABLE

[0,0]

 

0 = no; 1 = yes

 

 

 

 

 

 

 

Part. 1 Part.2

 

 

 

 

22

RF JAM OPTION

[0]

 

 

 

0 = no RF Jam detection; 1 = send RF Jam report

 

 

 

 

 

UL: must be 1 if wireless devices are used

 

 

 

 

 

 

 

 

 

23 QUICK (FORCED) BYPASS

24 RF HOUSE ID CODE

26 CHIME BY ZONE

27 POWERLINE CARRIER DEVICE (X–10)

HOUSE CODE

28 ACCESS CODE FOR PHONE MODULE

29 LONG RANGE RADIO OUTPUT

ZONE SOUNDS AND TIMING (31 – 39)

31 SINGLE ALARM SOUNDING per ZONE 32

33

– 3 – [0,0]

Part. 1 Part. 2

Part. 1 Part. 2 Common

[0]

[0]

[00]

(Partition 1 only)

[0]

[0]

[0]

[1]

0 = no quick bypass UL: must be “0”

1 = allow quick bypass (code + [6] + [#] )

00 = disable all wireless keypad usage

01–31 = using 5827, 5827BD or 5804BD keypad [00,00,00]

0 = no; 1 = yes (select zones to chime on zone list 3, using *81 Menu mode)

0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,

7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P UL: not for fire or UL installations

00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11 for "", or # + 12 for "#".

UL: must be “00” for UL Commercial Burg. installations

0 = disable; 1 = enable

0 = no UL: must be “0”; 1 = yes

0 = sounder stops at timeout;

1 = no sounder timeout UL: must be “1” for fire install.

0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min; 4 = 16 min;

UL: For residential fire alarm installation, must be set for a minimum of 4 min (option 1); for UL Commercial Burglary installations, must be minimum 16 min (option 4)

34

35

[60,60]

Part. 1

Part. 2

 

 

[30,30]

Part. 1

Part. 2

 

Common zones use same delay as partition 1.

00 - 96 = 0 - 96 secs; 97 = 120 secs

SIA Installations: minimum exit delay is 45 seconds

UL: see inst. instr. for requirements.

Common zones use same delay as partition 1.

00

- 96 = 0 - 96 seconds

 

97

= 120 seconds

SIA Installations:

98

= 180 seconds

minimum entry delay is

99

= 240 seconds

30 seconds

For UL Residential Burglary Alarm installations, must be set for a maximum of 30 seconds; entry delay plus dial delay should not exceed 1 min. For UL Commercial Burglar Alarm, total entry delay may not exceed 45 seconds.

36

37

[30,30]

Part. 1

Part. 2

 

[1,1]

See *35 Entry Delay 1 above for entries.

0 = no; 1 = yes

SIA Installations: must be enabled (enter 1)

38

[0,0]

0

= no; 1 = yes (wired keypads and RF)

2

= yes, RF only

 

Part. 1 Part. 2

39

POWER UP IN PREVIOUS STATE

[1]

 

 

DIALER PROGRAMMING (40 – 42)

UL: must be “1” for UL Commercial Burglar Alarm inst.

0 = no; 1 = yes UL: must be “1”

Do not fill unused spaces. Enter 0–9; #+11 for ''; #+12 for '#'; #+13 for a 2-second pause. If fewer than the maximum digits entered, exit the field by pressing []. The next data field number is displayed.

40 PABX ACCESS CODE

Enter up to 6 digits. To clear entries, press 40. If call waiting

used, enter “(#+11) 70” plus “# + 13” (pause).

41

PRIMARY PHONE No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

SECOND PHONE No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter up to 20 digits. To clear entries, press 41or 42respectively.

3

Page 3
Image 3
First Alert FA168CPS, FA148CP manual 352*5$00,1*250