Fisher & Paykel CG755 Table for the choice of injectors, Burners, 28-30/37, Cat II 2H3+

Models: CG755

1 36
Download 36 pages 44.51 Kb
Page 18
Image 18
Table for the choice of injectors

Table for the choice of injectors

GB

IE

 

 

Cat: II 2H3+

 

 

 

 

 

 

 

 

 

Gas type:

 

 

NOMINAL

REDUCED

Ø INJECTOR

 

GAS

 

BURNERS

POWER

POWER

 

PRESSURE

G20

 

(1/100 mm)

 

 

 

(HS - kW)

(HS - kW)

 

(mbar)

 

 

 

 

 

 

 

Auxiliary (A)

1,00

0,30

72 (X)

 

 

 

 

Semi-rapid (SR)

1,75

0,45

97 (Z)

 

20

 

 

Rapid (R)

3,00

0,75

115 (Y)

 

 

 

 

 

 

 

Triple ring (TR)

3,50

1,50

135 (T)

 

 

 

 

 

 

 

 

 

 

Gas type:

 

 

NOMINAL

REDUCED

Ø INJECTOR

 

GAS

 

BURNERS

POWER

POWER

 

PRESSURE

G30/G31

 

(1/100 mm)

 

 

 

(HS - kW)

(HS - kW)

 

(mbar)

 

 

 

 

 

 

 

Auxiliary (A)

1,00

0,30

50

 

 

 

 

Semi-rapid (SR)

1,75

0,45

65

 

28-30/37

 

 

Rapid (R)

3,00

0,75

85

 

 

 

 

 

 

 

Triple ring (TR)

3,50

1,50

95

 

 