Electrical connection

18

Installation instructions

Electrical connection

Important!

This appliance must be earthed.

Installation must be carried out according to the manufacturer’s instructions.

Incorrect installation may cause harm and damage to people, animals or property, for which the manufacturer accepts no responsibility.

If the installation requires alterations to the domestic wiring system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the power drawn by the appliance. Before carrying out any work on the electrical section of the appliance, it must be disconnected from the power supply.

The plug must be connected to an earthed socket in compliance with safety standards.

Do not use adapters, reducers, a multi-outlet power board or branching devices when connecting this appliance to the mains power supply, as doing so can cause overheating and burning.

The appliance must be connected to the mains power supply checking that the voltage corresponds to the value given in the rating plate and that the electrical cable sections can withstand the load specified on the plate.

If the appliance is supplied without a plug, fit a standard plug which is suitable for the power consumed by the appliance.

A suitable isolating switch providing full disconnection from the mains power supply must be incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. The switch must be of an approved type and provide a 3 mm air gap contact separation in all poles in accordance with the local wiring rules. The switch or socket must be accessible with the appliance installed.

The power supply cable must not touch any hot parts and must be positioned so that it does not exceed 75°C at any point along its length.

If the power supply cable is damaged, it must be replaced by a cable of the same type. It can only be replaced by the manufacturer, its Service Agent or a similarly qualified person in order to avoid a hazard.

As the colours of the wires in the power supply cable of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Colour of power supply cable wire

Colour or mark of plug terminal

Green & Yellow

“E” (Earth) or green or

 

 

 

 

 

 

Blue

“N” (Neutral) or black

Brown

“L” (Live) or red

Power supply cable section

230 V

 

 

 

 

 

 

 

 

 

 

 

 

Type H05V2V2-F, resistant to temperature of up to 90oC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230 V~ 50/60 Hz 3 x 0.75 mm2

L1 PE N(L2)

Fig. 10 Connection diagram