Installation instructions
Leak-testing and flame-testing the cooktop
Important!
13
The operation of the cooktop, including the ignition system, must be tested before installation is complete. If, after following the instructions below, satisfactory performance cannot be obtained, contact the local gas authority or your local Authorised Service Centre for advice and assistance.
Checking the connections for leaks
After installation and making all connections, check thoroughly for possible leaks and make sure all connections are
1Turn all control dials to O (OFF).
2 Open the valve on the gas supply.
3 Check each connection one at a time by brushing a soap and water solution or a suitable leak detection fluid over it.
Important!
Do not use any naked flames to check for leaks.
The presence of bubbles indicates a leak. Tighten or replace connections as appropriate, then
Checking the burner flames
1Light each burner.
2Check for a
If any abnormality is evident, check that:
-the burner cap is located properly
-the injector nipple is correctly aligned
-the correct size injectors are installed.
|
| Incorrect: flame |
|
|
| Incorrect: |
| Good flame: | |||||||||||
‘lifting off’ the burner |
|
|
| yellow tipping |
|
|
|
| without yellow tipping | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fig.4 Incorrect and good flame patterns