Fisher & Paykel CG905 Troubleshooting, indicators are flashing, Problem, Possible solutions

Models: CG905

1 36
Download 36 pages 43.24 Kb
Page 32
Image 32
Troubleshooting

30

Troubleshooting

Problem

Possible solutions

There is a power failure.

Models with auto-reignition (CG905DWAC)

 

The gas supply will be cut off, even if a burner is in use.

 

The cooktop cannot be used if there is a power failure. Wait

 

until power is restored.

 

If a control dial is still turned on when the power is restored,

 

the corresponding ‘Burner On’ indicator will flash rapidly.

 

Turn the burner off and light it again to resume cooking.

 

Models with flame failure protection (CG905DWFC, CG604DWFC)

 

You can still use your cooktop.

 

Light the burners by holding a match close to the side of the

 

burner and pressing down then turning the control dial to

 

HIGH. Wait until the flame is burning evenly before adjusting.

The flame has accidentally been extinguished.

Models with auto-reignition (CG905DWAC)

The auto-reignition system will detect this. The ignitors will spark and relight the burner.

If no flame is detected after about 5 seconds, the gas supply to the cooktop will be cut off and the ‘Burner On’ indicator will flash slowly. In this event, turn the burner off and relight it to resume cooking.

Models with flame failure protection (CG905DWFC, CG604DWFC)

The flame failure protection will automatically cut the gas supply to the burner off.

Turn the corresponding dial to O (OFF) and do not try to relight it for at least 1 minute (to allow the gas to disperse).

CG905DWAC models Turn all the control dials to O (OFF) and restart. only: All my ‘Burner On’

indicators are flashing.

Page 32
Image 32
Fisher & Paykel CG905 installation instructions Troubleshooting, indicators are flashing, Problem, Possible solutions