Converting to a different gas type

14

Installation instructions

Converting to a different gas type

Important!

Gas conversion may only be carried out by a suitably qualified and registered person.

To convert from one gas type to another, you need to replace the injectors and adjust the minimum burner setting.

To replace the injectors, you will need a 7 mm box spanner (and a 10 mm ring spanner for CG905DWAC models). These are not supplied.

1Disconnect the cooktop from the power supply.

Important!

Disconnect cooktop from the power supply before continuing.

2Make sure each control dial is turned to O (OFF).

3 Remove all the pan supports and burner heads.

4 Pull off the control dials.

5 Using a 7 mm box spanner, remove the injectors and replace them with the correct ones (size numbers are stamped on the inside, eg 70=0.70 mm). Hold on to the card housing the replacement injectors for later use.

CG905DWAC only

6Remove all the screws holding the burners in place.

7 Carefully lift the hob tray off the cooktop.

Important!

Beware of sharp edges.

8Replace the wok burner injector with the correct one using a 10 mm ring spanner.

9Reset the venturi. Loosen the venturi screw, move the venturi towards the injector approx. 2 mm.

10Refit the hob tray on the cooktop, repeating steps 6 and 7 in reverse. 11 Check insulation resistance and earth continuity.

12 Reconnect the cooktop to the power supply.

13 Refit the control dials.

14 Adjust the minimum burner setting. See section ‘Adjusting the minimum burner setting’ following.

15 Check that all burners have a good flame (Fig.4).

16 To indicate the gas type change, peel the adhesive label off the replacement injector card and apply it over the existing gas type label (on the underside of the cooktop).