Level machine

Check the dryer is level, and make necessary adjustments to the front levelling feet. The rear levelling feet are self adjusting.

Final installation check list

Check that:

No plastic or flexible metal foil is used in the exhaust ducting.

Exhaust is rigid ducting or thick wall flexible metal ducting.

All joints in the ducting are made with duct tape – no screws are used.

Ducting is clean and is connected to the dryer.

Inserts are fitted to the two front feet.

Dryer is level across the front.

Dryer is plugged into an approved fitting and is properly grounded.

Gas is turned on before attempting to start the dryer.

All fittings in the gas line are tested for leaks.

Dryer starts, heats, cools and shuts off.

Exhaust temperature increases, to confirm ignition has occurred.

If ignition does not occur initially, it may be due to air in the gas line or low voltage power supply.

The gas regulator valve may fail to open if the power supply falls below 105 Volts.

If the gas fails to flow or does not ignite, the dryer will automatically switch off.

Customer has been shown how to use the dryer.

NB: This dryer has a drum reversal feature to reduce clothes tangle. Throughout the drying cycle the motor will run for four minutes, then stop & run in the opposite direction for forty seconds before reversing again.