4.2Hardware Output Test Mode
Press and hold KEYLOCK, then START/PAUSE for 5 seconds. All LEDs & LCD segments except Keylock are illuminated. Press POWER once.
“HO” will show in the display (integrated and flat door models: Heavy, Normal, Fast, Delicate, Rinse LEDs showing).
Press START/PAUSE.
Scroll through the following outputs using Start/Pause. Turn the outputs on
&off using Keylock button. Press POWER to exit.
Note: Scrubbing brush symbol = output on, no scrubbing brush = output off (on integrated and flat door models a green LED above the start/pause button is used in place of the scrubbing brush).
LCD | Norm | Fast | Deli | Rinse |
| Hardware Output |
Display | LED | LED | LED | LED |
|
|
bL | Off | Off | Off | On |
| Backlight |
Er | Off | Off | On | Off |
| Element Relay |
Ld | Off | Off | On | On |
| Lid Motors (will run for 10 |
|
|
|
|
|
| seconds) |
dd | Off | On | Off | Off |
| Detergent Diverter Valve |
FU | Off | On | Off | On |
| Fill Water Valve |
|
|
|
|
|
| Motor Wash direction (2300- |
P1 | Off | On | On | Off |
| |
|
|
|
|
|
| 2850 rpm) |
P2 | Off | On | On | On |
| Motor Drain direction (4200 |
|
|
|
|
|
| rpm) |
|
|
|
|
|
| Rinse Aid Dispenser |
rd | On | Off | Off | Off |
| |
|
|
|
|
|
| (dispenses current setting) |
dF | On | Off | Off | On |
| Drying fan |
LE | On | Off | On | Off |
| Rinse Aid LED |
C1 | On | Off | On | On |
| Water Softener Diverter |
|
|
|
|
|
| Valve |
C2 | On | On | Off | Off | Water Softener Brine Pump | |
|
|
|
|
|
| Water Softener Brine Valve |
C3 | On | On | Off | On |
| |
|
|
|
|
|
| Displays current water |
°C | On | On | On | Off |
| |
|
|
|
|
|
| temperature. |
|
|
|
|
|
| Displays controller rail |
°E | On | On | On | On |
| |
|
|
|
|
|
| voltage |
Tub Home Sensor test:- Keylock symbol on = tub closed, off = tub open
15