599464
Fault | LED | Fault | Possible Causes |
Code | Display |
|
|
F7 | Fast, | No lid motor | • Lid actuator not connected. |
| Delicate | current | • PCB mains filter and controller |
| and Rinse | detected. | connectors. |
| LEDs. |
| • Faulty PCB mains filter. |
|
|
| • Faulty electronic controller. |
F8 | Normal | Earth leakage | • Test for earth leakage. |
| LED. | fault. | • Connectors and earth |
|
|
| connections fitted correctly. |
|
|
| • Damaged harnesses. |
|
|
| • Water damaged harness, |
|
|
| connector, or controller. |
F9 | Normal and | Power supply / | • Caused by F3, F8 or F9 faults. |
| Rinse LED. | controller fault. | • Check coils and motor |
|
|
| windings. |
|
|
| • Check lid actuators. |
|
|
| • Check controller for signs of |
|
|
| damage. |
|
|
| • Check PCB mains filter and |
|
|
| controller connectors. |
|
|
| • Check heater plate harness |
|
|
| and connectors. |
|
|
| • Replace electronic controller. |
|
|
| • Replace PCB mains filter. |
FF | Normal, | Top tub not | • Chassis harness or |
| Fast, | responding. | connectors. |
| Delicate |
| • Faulty top controller. |
| and Rinse |
| • Faulty PCB mains filter. |
| LEDs. |
|
|
20