F8 Earth Leakage Fault

Earth leakage fault.

The product will disable the power supply, log the fault, lock out the user and report to the user.

Note: The isolation relay will be disabled. Power to the product will need to be disconnected then reconnected for it to become fully functional again.

PRIMARY ACTION

- Test for earth leakage (using a Megger).

SECONDARY ACTION

-Check that the connectors are properly fitted and earthing connectors are fitted.

TERTIARY ACTION

-Check for physically damaged harnesses.

-Check for water damage to the harnesses, connectors, PCB mains filter and controllers.

-Check the heater plate tracks for water, damage.