Fisher & Paykel OR90SBDSIX Installation instructions, Connecting the power supply cable, 220-240

Models: OR90SBDSIX

1 60
Download 60 pages 11.19 Kb
Page 15
Image 15
Connecting the power supply cable

Installation instructions

Connecting the power supply cable

13

Important!

This cooker must be connected to the electricity supply only by an authorised person.

To connect the power supply cable to the cooker, it is necessary to:

1Unhook the terminal board cover by inserting a screwdriver into the two hooks ‘A’ (fig. 12).

2 Unscrew the screw ‘D’ and open completely the cable clamp ‘E’ (figs. 14).

3 Position the U bolts ‘F’ onto terminal board ‘G’ (figs. 14) according to the diagrams in fig. 13.

4 Connect the phase, neutral and earth wires to terminal board ‘G’ according to the diagrams in figs. 13 - 14.

5 Strain the feeder cable and block it with cable clamp ‘E’ (by screwing screw ‘D’). 6 Close the terminal block cover (check the two hooks ‘A’ are correctly hooked).

Important!

To connect the power supply cable DO NOT unscrew the screws fixing the cover plate behind the terminal block.

WARNING: If the power supply cable is damaged, it must be replaced only by an authorised service agent in order to avoid a hazard.

Voltage and power consumption

 

 

220-240/380-415 V 3N~

50/60 Hz

48,17 A (230 V)

11080 W (diversity not applied)

 

 

 

220-240 V

 

 

 

L1

1

 

 

 

2

 

 

 

 

3

 

 

 

 

4

 

 

 

N (L2)

5

 

 

 

PE

 

 

 

 

380-415 V 2N

 

 

 

L1

1

 

 

 

 

2

 

 

 

L2

3

 

 

 

 

4

 

 

 

N

5

 

 

 

PE

 

 

 

 

380-415 V 3N

 

 

 

L1

1

 

 

 

L2

2

 

A

 

L3

3

 

 

N

4

 

 

 

5

 

 

 

PE

 

Fig. 12 Terminal block

Fig. 13 Connection diagrams

 

 

 

 

Page 15