PROGRAMMABLE OPTIONS Cont.
29. Aux #4 Time control: (1 sec. to 255 sec.) Default = 12 seconds
This option determines the length of time that is outputted from Aux #4 (Green/White wire). Pressing the Lock or Unlock buttons on the remote raises or lowers the time by one second.
30. Turbo Timer Mode:
The optional Turbo Timer mode allows the CoolStart system to keep a Turbo or Turbo Diesel vehicle running for 1 to 5 minutes [selectively] after you remove the key and exit the vehicle. This is handy for turbo
31. Option Reset: RESTORE TO DEFAULT
This option allows you to restore all programmable options to factory default values. Go to the option 31 and press the Unlock Button #2 on the remote. The lights flash 2 times and all values will be reset to factory original settings. Default values are marked with asterisks in the chart on pages 20 and 21.
PROGRAMMABLE OPTION RESET
This system provides a reset method to restore all options to FACTORY DEFAULT VALUES as listed in the “Button #2” column of the programmable option chart on pages
1.Open hood (ground the Blue wire if no hood pin is installed)
2.Turn Key to the ON position (Pink ignition wire must be connected)
3.Press program / valet button 5 times, after a few seconds the unit will flash the lights 5 times.
4.Push the valet/program button 31 times. Press carefully, do not lose count! You must get a light flash each time you press the button. If the unit didn’t flash the lights, then the system did not register your press.
5.Press button #2 (Unlock) to reset the options. (Lights should flash twice)
6.Turn Ignition OFF, Close hood
25