WIRING: 9-PIN Connector Cont.

Green/Red: (-) 500mA Remote Aux. Output 1 (Programmable Option #10, requires relay)

This is a programmable output that can operate two different ways: 1 - (DEFAULT) Disarm with Remote Auxiliary Output that provides a ½ second (-) Negative pulse when Button #3 is pressed to open a Factory power trunk or hatch release. 2 - Remote Auxiliary Output without disarm

NEGATIVE AUXILARY OUTPUT

+12V CONSTANT

GREEN/RED

OR

(-) AUX OUTPUT

Trunk Soleniod

-OR-

Dome Light

-OR-

Aux Function

8586

30 87

+12V CONSTANT

OR *

*Test activation circuit in vehicle. Connect to+12V for Positive circuits or Ground for Negative circuits. Relay not included.

Blue/Black: (-) 500mA IGNITION OUT or REMOTE AUX. Output #2 (Programmable Option #17)

This wire functions as a Negative IGNITION OUTPUT (Ground while Remote Starting) for use when connecting factory Security Bypass modules or when an additional external Ignition Relay is required for your installation. This wire can be programmed to function as an AUXILIARY OUTPUT #2 providing a momentary (-) Negative output when Button #5 then #1 is pressed and held for more than 2 seconds. The Aux Channel #2 output stays on as long a the button is held down. Connect to the Negative activation circuit of an auxiliary module or device.

6

Page 6
Image 6
Fortress Technologies FS-50 manual Negative Auxilary Output +12V Constant GREEN/RED