OPTION PROGRAMMING TABLE
20 | PINK Wire function |
| Passive Carjack | *Glow Plug* |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
21 | Starter Cranking Time (Option |
| 0.75 Sec. | *0.5 Sec.* |
| 1.0 Sec. |
| 1.5 Sec. | |
#16 is set to Timed Crank) |
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
22 | Diesel Glow Plug Delay |
| 10 Seconds | *Monitor Glow |
| 20 Seconds |
| 30 Seconds | |
| Plug |
|
| ||||||
|
|
|
|
|
|
|
|
| |
23 | Remote Start Engine Run |
| 12 Minutes | *24 Minutes* |
| 36 Minutes |
| 48 Minutes | |
Time |
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
24 | Smart Tachless Voltage |
| 1% |
| *Set to 93% for |
|
| ||
Adjustment |
|
| default* |
|
| ||||
|
|
|
|
|
|
|
| ||
25 | Horn Pulse |
| Pulse With Trigger | No |
| *All Functions* |
| All Functions | |
| (No Chirps) |
|
| Short Chirp | |||||
|
|
|
|
|
|
| |||
26 | Aux # 3 |
| Steady Momentary | *Momentary* |
| Timed |
| Latch On/Off | |
|
|
|
|
|
|
|
|
|
|
27 | Aux # 3 Time : 1 to 255 sec. |
| +1 Second |
| *Default 12 Sec.* |
|
| ||
|
|
|
|
|
|
|
|
|
|
28 | Aux # 4 |
| Steady Momentary | *Momentary* |
| Timed |
| Latch On/Off | |
29 | Aux # 4 Time : 1 to 255 sec. |
| +1 Second |
| *Default 12 Sec.* |
|
| ||
30 | Turbo Timer Mode |
| Brake Pedal Set Mode | *Always Set Mode* |
| Idle Down Mode |
|
| |
1 to 5 Minutes |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
31 | Reset Options to default (*) |
|
|
| *Reset All |
|
|
|
|
|
|
| Options* |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
PROGRAMMABLE OPTION DESCRIPTIONS:
1. ENGINE MONITORING:
This option sets how the unit monitors your engine. You can program either for Tach mode in which the unit uses a Tach signal (RPM) or for
2. AUTOLOCK/UNLOCK W/IGNITION:
Controls whether the doors will automatically lock when the ignition is turned on and unlock when the ignition is turned off. Doors will not lock if they are open to prevent locking the keys in.