| Default: A6 = 0. |
A7 | External alarm detection delay. |
| Not used by foster |
| Default: A7 = 0. |
A8 | Enables alarm ‘Ed1’ and ‘Ed2’. |
| Not used by Foster. |
| Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled. |
Ado | Door switch light management mode. |
| Not used by Foster. |
| Default: Ado = 0. |
Ac | High condenser temperature alarm. |
| Not used by Foster. |
| Default: Ac = 70.0. |
AE | High condenser alarm temperature differential. |
| Not used by Foster. |
| Default: AE = 5.0. |
Acd | High Condenser temperature alarm delay. |
| Not used by Foster. |
| Default: Acd = 0. |
AF | Off time with light sensor. |
| Not used by Foster. |
| Default: AF = 0. |
F0 | Fan management. |
| F0 = Fan runs all of the time, for fans during defrost see ‘F3’. |
| Default: F0 = 0. |
F1 | Fan start temperature. |
| Used in conjunction with ‘F0’ when ‘F0’ = 1. |
| Default: F0 = 5.0. Fans remain ON while the evaporator is 5 degrees colder than the room temperature. |
F2 | Fans off with compressor off. |
| Used in conjunction with ‘F0’. |
| Default: F2 = 1. Foster setting F2 = 0 fans are always ON (F0 =0). |
F3 | Fans in defrost. |
| Used to determine if the fans operate or not during defrost. |
| Default: F3 = 1. Fans do not operate during defrost. |
Fd | Fans off after dripping. |
| Fans can be stopped for a further period, in minutes, after defrost beyond what has been set in ‘dd’. |
| Default: Fd = 1 = 1 additional minute dripping time. |
H0 | Serial address. |
| Used to assign an address to the instrument so that it responds to when connected to a supervisory or |
| telemaintenance system. |
| Default: H0 = 1. Foster setting H0 = 30. |
H1 | Function of relay 4. |
| Auxiliary output used to power the doorframe lighting and frame heater. |
| Default: H1 = 1. Foster setting H1 = 2. |
H2 | Disable keypad / infra red. |
| Can be used to inhibit some functions relating to the use of the keypad. |
| Default: H2 = 1 = all enabled. |
H3 | Remote control enabling code. |
| Assigns an access code to the remote control if fitted. |
| Not used by Foster. |
12