Foster FHG 2L, FHG 3L manual External alarm detection delay

Models: FHG 2L FHG 3L

1 20
Download 20 pages 7.39 Kb
Page 13
Image 13

 

Default: A6 = 0.

A7

External alarm detection delay.

 

Not used by foster

 

Default: A7 = 0.

A8

Enables alarm ‘Ed1’ and ‘Ed2’.

 

Not used by Foster.

 

Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled.

Ado

Door switch light management mode.

 

Not used by Foster.

 

Default: Ado = 0.

Ac

High condenser temperature alarm.

 

Not used by Foster.

 

Default: Ac = 70.0.

AE

High condenser alarm temperature differential.

 

Not used by Foster.

 

Default: AE = 5.0.

Acd

High Condenser temperature alarm delay.

 

Not used by Foster.

 

Default: Acd = 0.

AF

Off time with light sensor.

 

Not used by Foster.

 

Default: AF = 0.

F0

Fan management.

 

F0 = Fan runs all of the time, for fans during defrost see ‘F3’.

 

Default: F0 = 0.

F1

Fan start temperature.

 

Used in conjunction with ‘F0’ when ‘F0’ = 1.

 

Default: F0 = 5.0. Fans remain ON while the evaporator is 5 degrees colder than the room temperature.

F2

Fans off with compressor off.

 

Used in conjunction with ‘F0’.

 

Default: F2 = 1. Foster setting F2 = 0 fans are always ON (F0 =0).

F3

Fans in defrost.

 

Used to determine if the fans operate or not during defrost.

 

Default: F3 = 1. Fans do not operate during defrost.

Fd

Fans off after dripping.

 

Fans can be stopped for a further period, in minutes, after defrost beyond what has been set in ‘dd’.

 

Default: Fd = 1 = 1 additional minute dripping time.

H0

Serial address.

 

Used to assign an address to the instrument so that it responds to when connected to a supervisory or

 

telemaintenance system.

 

Default: H0 = 1. Foster setting H0 = 30.

H1

Function of relay 4.

 

Auxiliary output used to power the doorframe lighting and frame heater.

 

Default: H1 = 1. Foster setting H1 = 2.

H2

Disable keypad / infra red.

 

Can be used to inhibit some functions relating to the use of the keypad.

 

Default: H2 = 1 = all enabled.

H3

Remote control enabling code.

 

Assigns an access code to the remote control if fitted.

 

Not used by Foster.