Foster FHG 2L, FHG 3L manual Technical Specification

Models: FHG 2L FHG 3L

1 20
Download 20 pages 7.39 Kb
Page 3
Image 3

Introduction

The display case are manufactured in two formats FHG 2L, 2 doors, and the FHG 3L, three doors.

There are also Multiplex options that are a combination of two FHG 2L cases to make a FHG 4L or a combination of the FHG 2L and FHG 3L to make a FHG 5L.

Technical Specification.

Model

 

2 Door

3 Door

4 Door

5 Door

External Dimensions (m)

Height (m)

2100

2100

2100

2100

 

Width (m)

1684

2463

3254

4035

 

Depth (m)

900

900

900

900

Internal Dimensions (m)

Height (m)

1354

1354

1354

1354

 

Width (m)

1564

2343

3128

3907

 

Depth (m)

550

550

550

550

No. of Shelves

 

12

18

24

30

Shelf capacity (each)

Kg

40

40

40

40

Door System

 

Schott

Schott

Schott

Schott

Refrigeration System

 

 

 

 

 

 

 

Hitachi

 

Hitachi FL200

 

 

Up to Aug

 

DL

 

Compressor

FL200 DL

 

 

2004

 

400v 3 phase

 

 

400v 3 phase

 

 

 

 

 

(x 2)

 

 

 

 

 

 

 

 

Hitachi

 

Hitachi

 

 

From Aug

 

DS 183651

 

 

DS 183651

 

 

 

2004

 

230v 1 phase

 

 

230v 1 phase

 

 

 

 

 

(x 2)

 

 

 

 

 

 

 

 

 

Hitachi

 

Hitachi

 

 

 

 

FL300DL

 

 

 

FL300DL

 

 

 

 

 

400 3 Phase

 

 

 

400 3 Phase

 

 

 

 

 

(x 2)

 

 

 

 

 

 

 

R404A

R404A

R404A

R404A

Refrigerant

 

2500 grms

2500 grms +

 

2500 grms

3500 grms

 

 

(x 2)

3500 grms

 

 

 

 

Vaporisation

 

Hot Gas

Hot Gas

Hot Gas

Hot Gas

 

 

Hot Gas and

Hot Gas and

Hot Gas and

Hot Gas and

Defrost Type

 

Electric

Electric

Electric

 

Electric (1 kW)

 

 

( 1.5 kW)

(2.1kW)

(2.5 kW)

 

 

 

Electrical supply

 

230/1/50

400/3/50

230/1/50 X 2

400/3/50 +

 

230/50/1

 

 

 

 

 

Electrical Supply Capacity

 

16A

16A

16A

16A

Controller

 

Carel

Carel

Carel

Carel

 

PB00F0HB10

PB00F0HB10

PB00F0HB10

PB00F0HB10

 

 

Heat loads & Consumption

 

 

 

 

 

Lighting

Watts

140

210

280

350

Door frame heaters

Watts

266

380

522

646

Fan motors

Watts

132

198

264

330

Compressor consumption

Watts

 

2760

 

 

Compressor Duty

Watts

 

2660

 

 

Compressor Current

A

 

5.1

 

 

2