Setting the set point.

9.Compressor: Illuminated when the compressor is running. Flashes when the activation of the compressor is delayed by safety times.

10.Programming the controller. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to external disabling or procedures in progress.

11.Manual background DEFROST: Illuminated when defrost is activated. Flashes when the activation of the defrost is prevented due to external disabling or procedures in progress.

12.Manual background AUX: Illuminated when the auxiliary output (1 and/or 2) selected as AUX is activated.

13.ALARM: Illuminated following the activation of the external digital input alarm. Flashes in the event of alarms during normal operation (e.g. high /low temperature) or in the event of alarms from an external digital input, immediate or delayed.

14.Manual background CLOCK: Illuminated if at least one timed defrost has been set. On start up comes ON for a few seconds to indicate that the Real Time Clock is active.

15.Manual background LIGHT: Illuminated when the auxiliary output (1 and /or 2) is selected as the LIGHT is activated.

16.Manual background SERVICE: Flashes in the event of a malfunction, for example EPROM errors or probe faults.

17.DISPLAY: Displays the temperature in the range –50 to +150°C. the temperature is displayed to the tenth of a degree between –19.9 and + 19.9°C. the display of the tenths can be disabled by setting the related parameter.

18.Manual background HACCP: Illuminated if the HACCP function is enabled. Flashes when there are hew HACCP alarms stored (HA and/or HF alarm shown on the display).

19.Manual background CONTINUOUS CYCLE:Illuminated when the CONTINUOUS CYCLE function is activated. Flashes if the activation of the function is prevented due to external disabling or procedures in progress (e.g. minimum compressor OFF time).

Setting the set point.

To display the set point proceed as follows:

1.Press Manual background for more than 1 second to display the set point.

2.To increase the set point press Manual background or to decrease the set point press Manual background until the desired value is reached.

3.To confirm the value press Manual background.

Programming the controller.

The parameters can be modified using the front keypad.

The operating parameters are divided into two families: Frequent parameters (type “F”) and configuration parameters (type “C”).

Access to the configuration parameters is protected by a password that prevents unwanted modification or access by unauthorised persons.

Accessing the type “F” parameters.

Press Manual background for more than 5 seconds (if an alarm is active, the buzzer is muted), the display shows the code of the first modifiable type “F” parameter.

Accessing the type “C” parameters.

1.Press Manual background and Manual background together for more than 5 seconds; the display will show the number “00”.

2.Press Manual background until the display shows “22” ( the code allows access to the parameters)

4

Page 5
Image 5