Temperature controller
It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained.
Carel PB00F0HB10
15
1314
1 2 3 4
9
10
12
11
16 | 17 | 18 | 19 | 5 | 6 | 7 | 8 |
Controller Display and Symbols.
NOTE: When the buttons are pressed a brief audible signal is emitted; this signal can not be disabled.
1.HACCP: Pressing this button displays a sub menu used to access the HACCP parameters (not used by Foster)
2. ON/OFF: When pressed for more than 5 seconds switches the controller on/off. When OFF the controller display alternates between “OFF” and the air temperature as read by the air probe.
3. PRG/MUTE: Mutes the audible alarm and deactivates the alarm relay.
:If pressed for more than 1 second the during the reception of the automatic network address assignment request package, starts the address assignment procedure (not used by Foster).
:If pressed for more than 5 seconds, allows access to the menu for setting the “F” (frequent) parameters.
:If pressed for more than 5 seconds together with, allows access for setting the “C” (configuration) Parameters.
:If pressed for more than 5 seconds when switching the instrument ON, activates the procedure for setting the default parameter values.
:If pressed for more 5 seconds together with, resets any active alarm with manual reset (the message ‘rES ‘ indicates that the alarm has been reset); any delays relating to the alarms are
4. UP/CC: If pressed for more than 5 seconds, activates/deactivates the continuous cycle operation (the message ‘ccE’ and ‘ccE’ indicate, respectively, the start and end of the continuous cycle request).
: If pressed together with, for more than 5 seconds, starts the report printing procedure (provided the printer interface is connected to the controller).
:If pressed for more than 5 seconds together with, resets any active alarm with manual reset (the message ‘rES ‘ indicates that the alarm has been reset); any delays relating to the alarms are re- activated.
5. Light: If pressed for more than
6. AUX: If pressed for more than
7. DOWN/DEF: If pressed for mare than 5 seconds, activates/deactivates a manual defrost (the message ‘dFb’ and dFE’ indicate, respectively, the start and end of defrost).
8. SET: If pressed for more than 1 second displays and/or sets the set point.
:If pressed for more than 5 seconds together with , accesses the menu for setting the type ”C” (configuration) parameters.
: If pressed together with for more than 5 seconds, starts the report printing procedure (provided the printer interface is connected to the controller).
3