Foster FHG 3L, FHG 2L manual Controller Display and Symbols, Temperature controller

Models: FHG 2L FHG 3L

1 20
Download 20 pages 7.39 Kb
Page 4
Image 4
Temperature controller

Temperature controller

It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained.

Carel PB00F0HB10

15

1314

1 2 3 4

9

10

12

11

16

17

18

19

5

6

7

8

Controller Display and Symbols.

NOTE: When the buttons are pressed a brief audible signal is emitted; this signal can not be disabled.

1.HACCP: Pressing this button displays a sub menu used to access the HACCP parameters (not used by Foster)

2.Controller Display and Symbols. ON/OFF: When pressed for more than 5 seconds switches the controller on/off. When OFF the controller display alternates between “OFF” and the air temperature as read by the air probe.

3. Manual background PRG/MUTE: Mutes the audible alarm and deactivates the alarm relay.

:If pressed for more than 1 second the during the reception of the automatic network address assignment request package, starts the address assignment procedure (not used by Foster).

:If pressed for more than 5 seconds, allows access to the menu for setting the “F” (frequent) parameters.

:If pressed for more than 5 seconds together with, Manual backgroundallows access for setting the “C” (configuration) Parameters.

:If pressed for more than 5 seconds when switching the instrument ON, activates the procedure for setting the default parameter values.

:If pressed for more 5 seconds together with, Manual background resets any active alarm with manual reset (the message ‘rES ‘ indicates that the alarm has been reset); any delays relating to the alarms are re-activated.

4.Manual background UP/CC: If pressed for more than 5 seconds, activates/deactivates the continuous cycle operation (the message ‘ccE’ and ‘ccE’ indicate, respectively, the start and end of the continuous cycle request).

: If pressed together with, for more than 5 seconds, starts the report printing procedure (provided the printer interface is connected to the controller).

:If pressed for more than 5 seconds together with,Manual background resets any active alarm with manual reset (the message ‘rES ‘ indicates that the alarm has been reset); any delays relating to the alarms are re- activated.

5. Manual background Light: If pressed for more than 1-second activates/deactivates auxiliary output 2.

6.Manual background AUX: If pressed for more than 1-second activates/ deactivates auxiliary output 1.

7.Manual background DOWN/DEF: If pressed for mare than 5 seconds, activates/deactivates a manual defrost (the message ‘dFb’ and dFE’ indicate, respectively, the start and end of defrost).

8.Manual background SET: If pressed for more than 1 second displays and/or sets the set point.

:If pressed for more than 5 seconds together with , accesses the menu for setting the type ”C” (configuration) parameters.

: If pressed together with for more than 5 seconds, starts the report printing procedure (provided the printer interface is connected to the controller).

3

Page 4
Image 4
Foster FHG 3L, FHG 2L manual Controller Display and Symbols, Temperature controller