Foster FHG 3L, FHG 2L manual

Models: FHG 2L FHG 3L

1 20
Download 20 pages 7.39 Kb
Page 8
Image 8

35

c9

Enable autostart with PD operation

flag

0

0

0

36

c10

Select Pd by time or pressure

flag

0

0

0

37

c11

Delayed compressor delay

sec

4

4

4

 

 

 

 

 

 

 

38

d0

Type of defrost

flag

0

1

1

39

dI

Interval between defrosts

hours

8

6

6

40

dt1

End defrost temperature, evaporator.

°C/°F

4.0

20.0

20.0

41

dt2

End defrost temperature, aux. evaporator

°C/°F

4.0

4.0

4.0

42

dp1

Maximum defrost duration, evaporator

min

30

20

20

43

dp2

Maximum defrost duration, aux. Evaporator

min

30

30

30

44

d3

Defrost start delay

min

0

0

0

45

d4

Enable defrost at start up

flag

0

0

0

46

d5

Defrost delay at start up

min

0

0

0

47

d6

Display off during defrost

-

1

1

1

48

dd

Dripping time after defrost

min

2

1

1

49

d8

Bypass alarm after defrost

hours

1

1

1

50

d9

Defrost priority over compressor protection

flag

0

0

0

51

d/1

Display defrost probe

°C/°F

-

-

-

52

d/2

Display defrost probe

°C/°F

-

-

-

53

dC

Base time for defrost

flag

0

0

0

54

d10

Compressor running time

hours

0

0

0

55

d11

Running time temperature threshold

°C/°F

1.0

1.0

1.0

56

d12

Advanced defrost

-

0

0

0

57

dn

Nominal defrost time

-

65

65

65

58

dH

Proportional factor for variation in ‘dI’

-

50

50

50

 

 

 

 

 

 

 

59

A0

Alarm and fan differential

°C/°F

2.0

4.0

4.0

60

A1

Type of threshold for ‘AL’ and ‘AH’

flag

0

0

0

61

AL

Low temperature alarm threshold

°C/°F

0.0

0.0

0.0

62

AH

High temperature alarm threshold

°C/°F

0.0

0.0

0.0

63

Ad

Low and high temperature alarm delay

min

120

120

120

64

A4

Configuration of digital input 1

-

0

0

0

65

A5

Configuration of digital input 2

-

0

0

0

66

A6

Stop compressor from external alarm

min

0

0

0

67

A7

External alarm detection delay

min

0

0

0

68

A8

Enable alarms ‘Ed1’ and Ed2’

flag

0

0

0

69

Ado

Door switch light management mode

flag

0

0

0

70

Ac

High condenser temperature alarm

°C/°F

70.0

70.0

70.0

71

AE

High condenser alarm temperature differential

°C/°F

5.0

5.0

5.0

72

Acd

High condenser temperature alarm delay

min

0

0

0

73

AF

Off time with light sensor

sec

0

0

0

 

 

 

 

 

 

 

74

F0

Fan management

flag

0

0

0

75

F1

Fan start temperature

°C/°F

5.0

5.0

5.0

76

F2

Fan off with compressor off

flag

1

0

0

77

F3

Fans in defrost

flag

1

1

1

78

Fd

Fans off after dripping

min

1

1

1

 

 

 

 

 

 

 

79

H0

Serial address

-

1

30

30

80

H1

Function of relay 4

flag

1

2

2

81

H2

Disable key / infra red

flag

1

1

1

82

H3

Remote control enabling code

-

0

0

0

83

H4

Disable buzzer

flag

0

0

0

84

H5

Function of relay 5

-

3

3

3

85

H6

Lock out buttons

-

0

0

0

86

H7

Select PD by time or pressure

flag

0

0

0

87

HPr

Print profile

-

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The total number of parameters is 105. For ease of set up Foster only use the ones listed. The remaining are not used and adjustment is not recommended.