35 | c9 | Enable autostart with PD operation | flag | 0 | 0 | 0 |
36 | c10 | Select Pd by time or pressure | flag | 0 | 0 | 0 |
37 | c11 | Delayed compressor delay | sec | 4 | 4 | 4 |
|
|
|
|
|
|
|
38 | d0 | Type of defrost | flag | 0 | 1 | 1 |
39 | dI | Interval between defrosts | hours | 8 | 6 | 6 |
40 | dt1 | End defrost temperature, evaporator. | °C/°F | 4.0 | 20.0 | 20.0 |
41 | dt2 | End defrost temperature, aux. evaporator | °C/°F | 4.0 | 4.0 | 4.0 |
42 | dp1 | Maximum defrost duration, evaporator | min | 30 | 20 | 20 |
43 | dp2 | Maximum defrost duration, aux. Evaporator | min | 30 | 30 | 30 |
44 | d3 | Defrost start delay | min | 0 | 0 | 0 |
45 | d4 | Enable defrost at start up | flag | 0 | 0 | 0 |
46 | d5 | Defrost delay at start up | min | 0 | 0 | 0 |
47 | d6 | Display off during defrost | - | 1 | 1 | 1 |
48 | dd | Dripping time after defrost | min | 2 | 1 | 1 |
49 | d8 | Bypass alarm after defrost | hours | 1 | 1 | 1 |
50 | d9 | Defrost priority over compressor protection | flag | 0 | 0 | 0 |
51 | d/1 | Display defrost probe | °C/°F | - | - | - |
52 | d/2 | Display defrost probe | °C/°F | - | - | - |
53 | dC | Base time for defrost | flag | 0 | 0 | 0 |
54 | d10 | Compressor running time | hours | 0 | 0 | 0 |
55 | d11 | Running time temperature threshold | °C/°F | 1.0 | 1.0 | 1.0 |
56 | d12 | Advanced defrost | - | 0 | 0 | 0 |
57 | dn | Nominal defrost time | - | 65 | 65 | 65 |
58 | dH | Proportional factor for variation in ‘dI’ | - | 50 | 50 | 50 |
|
|
|
|
|
|
|
59 | A0 | Alarm and fan differential | °C/°F | 2.0 | 4.0 | 4.0 |
60 | A1 | Type of threshold for ‘AL’ and ‘AH’ | flag | 0 | 0 | 0 |
61 | AL | Low temperature alarm threshold | °C/°F | 0.0 | 0.0 | 0.0 |
62 | AH | High temperature alarm threshold | °C/°F | 0.0 | 0.0 | 0.0 |
63 | Ad | Low and high temperature alarm delay | min | 120 | 120 | 120 |
64 | A4 | Configuration of digital input 1 | - | 0 | 0 | 0 |
65 | A5 | Configuration of digital input 2 | - | 0 | 0 | 0 |
66 | A6 | Stop compressor from external alarm | min | 0 | 0 | 0 |
67 | A7 | External alarm detection delay | min | 0 | 0 | 0 |
68 | A8 | Enable alarms ‘Ed1’ and Ed2’ | flag | 0 | 0 | 0 |
69 | Ado | Door switch light management mode | flag | 0 | 0 | 0 |
70 | Ac | High condenser temperature alarm | °C/°F | 70.0 | 70.0 | 70.0 |
71 | AE | High condenser alarm temperature differential | °C/°F | 5.0 | 5.0 | 5.0 |
72 | Acd | High condenser temperature alarm delay | min | 0 | 0 | 0 |
73 | AF | Off time with light sensor | sec | 0 | 0 | 0 |
|
|
|
|
|
|
|
74 | F0 | Fan management | flag | 0 | 0 | 0 |
75 | F1 | Fan start temperature | °C/°F | 5.0 | 5.0 | 5.0 |
76 | F2 | Fan off with compressor off | flag | 1 | 0 | 0 |
77 | F3 | Fans in defrost | flag | 1 | 1 | 1 |
78 | Fd | Fans off after dripping | min | 1 | 1 | 1 |
|
|
|
|
|
|
|
79 | H0 | Serial address | - | 1 | 30 | 30 |
80 | H1 | Function of relay 4 | flag | 1 | 2 | 2 |
81 | H2 | Disable key / infra red | flag | 1 | 1 | 1 |
82 | H3 | Remote control enabling code | - | 0 | 0 | 0 |
83 | H4 | Disable buzzer | flag | 0 | 0 | 0 |
84 | H5 | Function of relay 5 | - | 3 | 3 | 3 |
85 | H6 | Lock out buttons | - | 0 | 0 | 0 |
86 | H7 | Select PD by time or pressure | flag | 0 | 0 | 0 |
87 | HPr | Print profile | - | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: The total number of parameters is 105. For ease of set up Foster only use the ones listed. The remaining are not used and adjustment is not recommended.
7