Franke Consumer Products FCR 708-H TC manual Hood body assembly, Connection

Models: FCR 708-H TC

1 56
Download 56 pages 35.54 Kb
Page 6
Image 6
Hood body assembly

Hood body assembly

Adjust the two screws Vr of brackets 11a, by just placing them in position.

Hook the hood body to the two brackets 11a.

Pull the Comfort Panel to open it, remove the filters one by one, push them towards the rear part of the unit and pull downwards at the same time .

From inside the hood body, tighten the screws Vr to level the body.

Connection

AIR OUTLET IN A DUCTING HOOD VERSION

When installing the hood in ducting version, basing on the in- staller’s choice, a rigid or a flexible pipe with a ø 150 or 120 mm is used in order to connect the hood to the air outlet piping. The pipe connection can be made on the upper part or on the rear side of the hood.

Before connecting the hood to the air outlet ducting remove the lateral air outlet grid 8 and the plastic tube 7. The adapting flange 9 has to be removed only in case the connecting diameter is 150.

REAR AIR OUTLET

When drilling the air outlet hole in the wall proceed in accor- dance with the scheme in the part concerning the wall drilling.

Use a pair of tongs when breaking the rear air outlet hole in the wall.

In case the connection is made by using a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet.

Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood.

Remove the charcoal filter if present.

Fix the metal cover 10 to the upper air outlet hole of the hood by using the screws supplied.

UPPER AIR OUTLET

In case the connection is made by using a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet.

Use a pair of tongs when removing the central part of the metal cover 10. Fix the cover to the air outlet hole of the hood by us- ing the screws supplied.

Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood.

Remove the charcoal filter if present.

EN

11a

Vr

ø 150

9

ø 120

10

10

6

6

Page 6
Image 6
Franke Consumer Products FCR 708-H TC manual Hood body assembly, Connection, Air Outlet In A Ducting Hood Version