Charcoal filter (recycling version)
This filter cannot be washed or regenerated. It must be replaced when the C appears on the display or at least once every 4 months. The filter saturation alarm has to be activated already before.
Activation of the alarm signal
•In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.
•Switch off the hood and the lights.
•Press the
•By releasing the
•Within 3 seconds press the
•
•
CHANGING THE ACTIVATED CHARCOAL FILTER |
|
|
Resetting the alarm signal |
|
|
• Press button G and hold it for at least 2 seconds. |
|
|
Changing the Filter |
|
|
• If closed, open the Carriage by pressing button A and holding | B | A |
for at least 1.5 seconds (see USE). | ||
• Open the comfort panel. |
|
|
• Remove the grease filters. |
|
|
• Remove the saturated Activated Charcoal Filters, as indicated |
|
|
(A). |
|
|
• Fit the new Filters, as indicated (B). |
|
|
• Replace the metal grease filters. |
|
|
• Close the comfort panel. |
|
|
Lighting
LIGHT REPLACEMENT
20 W halogen light.
•Extract the lamp from the lamp holder by pulling gently.
•Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
EN