PXDR10 Drain Kit Installation Instructions (optional for new construction)

NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building. Follow appropriate instructions below depending on your particular type of installation.

Internal Drain

NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed.

1.Refer to Figure 11 and locate the drain within the “Preferred” area of best drainage. Maintain at least a ½” clearance from the embossed area.

2.Using the mounting plate with the ½” hole as a template, mark and drill two, 3/16” mounting holes and a ½” drain hole in the sleeve bottom.

3.Remove the backing from the gasket and mount it on the flat side of the mounting plate. (See Figure 12, Page 11). Insert the drain tube through the hole in the gasket and mounting plate so the tube flange will be against the wall sleeve.

4.Position the assembly beneath the drilled holes and secure it with #10-24 x ½" machine screws and lock nuts provided. Seal the tops of the screws with silicone caulking.

5.Use ½" I.D. copper tube, PVC pipe, or vinyl hose (obtained locally) to connect the internal drain tube to the drain system in the building.

6.Referring to Figure 12, Detail A, Page 11, locate and assemble the

(2) two cover plates and gaskets over the drain holes at the rear of the wall sleeve. Attach them with the #10 sheet metal screws provided. Make certain that the four overflow slots at the rear of the wall sleeve are not blocked (See drawing of the back of the sleeve Figure 12, Page 11).

7.If a deep wall extension (PDXWSEXT) is used, after installing the field supplied flashing, caulk as required. Be sure to caulk around the flashing and the wall sleeve where the hole was drilled for the drain tube.

Figure 11

Drain Kit Location and Installation

OPTIONAL AREA

PREFERRED AREA-

NO FOAM INSULATION

IF THE DRAIN MUST BE

 

LOCATED IN THE OPTIONAL

 

AREA, THE FOAM INSULATION

 

MUST BE CUT AWAY AND

3"

REMOVED TO ALLOW ACCESS

TO THE DRAIN.

 

SCREW

WALL SLEEVE

GASKET

MOUNTING

PLATE

DRAIN TUBE

NUT

SIDE VIEW

 

 

FRONT VIEW

 

 

FRP011

 

 

 

 

 

 

 

 

PXDR10

 

QUANTITY

DESCRIPTION

 

2

COVER PLATES

 

1

MOUNTING PLATE

 

1

DRAIN TUBE

 

3

MOUNTING PLATE GASKET

 

4

#10 X ½” SHEET METAL SCREWS

 

2

#10-24 X ½ ” MACH. SCREWS

 

2

#10-24 X ½" LOCKNUTS

10

Page 10
Image 10
Friedrich 920-087-09 (12/10) operation manual Internal Drain, Drain Kit Location and Installation

920-087-09 (12/10) specifications

The Friedrich 920-087-09 (12/10) is a remarkable air conditioning unit that exemplifies innovation in climate control technology. Designed for both residential and commercial environments, this model stands out for its efficiency, reliability, and user-friendly features.

One of the key characteristics of the Friedrich 920-087-09 is its impressive cooling capacity. With a nominal cooling power of 12,000 BTU, it is ideal for medium to large spaces, effortlessly maintaining comfortable indoor temperatures even during the hottest months. The unit offers a seasonal energy efficiency ratio (SEER) that meets contemporary standards, ensuring that it operates efficiently while consuming less energy. This feature not only lowers electricity bills but also reduces the overall environmental impact.

The Friedrich 920-087-09 is equipped with advanced inverter technology, allowing it to adjust its cooling power according to the temperature needs of the room. This results in quieter operation and enhanced energy savings as the unit avoids the frequent on-off cycles typical of conventional systems. Furthermore, the unit boasts a variable-speed compressor that guarantees consistent performance and improved humidity control.

Another standout feature of the Friedrich 920-087-09 is its sophisticated air filtration system. It includes a washable filter that captures dust, pollen, and other airborne particles, promoting cleaner air quality. This is particularly beneficial for those with allergies or respiratory issues, creating a healthier living environment.

The unit also features a customizable digital thermostat that allows users to set precise temperature preferences. With its user-friendly interface, users can easily switch between different modes, including cooling, heating, and dehumidifying, adding to the flexibility of the system. Additionally, Friedrich's exclusive Quiet Master technology minimizes noise levels, making it suitable for bedrooms, offices, and other quiet areas.

The Friedrich 920-087-09 also comes with a range of connectivity options, including Wi-Fi integration. This functionality allows users to control the air conditioning unit remotely through a smartphone app, making it exceptionally convenient for those with busy lifestyles.

Overall, the Friedrich 920-087-09 (12/10) combines cutting-edge technology, energy efficiency, and a host of user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort. Its design is not only functional but also aesthetically pleasing, allowing it to blend seamlessly with a variety of interiors.