Friedrich 920-087-09 (12/10) Alternate Wall Installations, Panel Wall, Frame and Brick Veneer

Models: 920-087-09 (12/10)

1 36
Download 36 pages 5.9 Kb
Page 7
Image 7
Alternate Wall Installations

Alternate Wall Installations

Figure 4

Panel Wall

OPTIONAL SUBBASE

LEVELING SCREW

FRP003

Figure 5

Frame and Brick Veneer

1/4" MIN PROJECTION

WOOD FRAME

STEEL

LINTEL

11" MIN.

Panel Wall WITH SUBBASE

OPTIONAL SUBBASE

LEVELING SCREW

FRP005

Figure 6

Curtain Wall

WALL OR

1/4" MIN

WINDOW

PROJECTION

CASE FLANGE (BY OTHERS)

OPTIONAL SUBBASE

LEVELING SCREW

FRP004

Figure 7

Block and Brick Veneer

1/4" MIN PROJECTION

CONCRETE LINTEL

STEEL

LINTEL

13-3/4" MIN.

Frame and Brick Veneer WITHOUT SUBBASE

RECEPTACLE

FINISHED FLOOR

POWER SUPPLY CONDUIT

(SUPPLIED BY INSTALLER)

 

 

FRP006

NOTE:

Follow all wall system manufacturer installation instructions. For sunrooms and modular buildings, adhere to their installation instructions for

 

supporting and sealing sleeve to their frames. All wall and window/wall installations must provide for proper drainage. In applications where the

 

drain holes on the PTAC wall sleeve are not exposed beyond the wall an internal drain system is recommended. It is the installer's responsibility

 

to ensure there is adequate drainage for the PTAC unit.

7

Page 7
Image 7
Friedrich 920-087-09 (12/10) Alternate Wall Installations, Panel Wall, Frame and Brick Veneer, Curtain Wall