Friedrich HEAT&COOLING MODEL INVERTER (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE En-3

Models: HEAT&COOLING MODEL INVERTER (REVERSE CYCLE) ROOM AIR CONDITIONER WALL MOUNTED TYPE

1 50
Download 50 pages 34.28 Kb
Page 4
Image 4
NAME OF PARTS

NAME OF PARTS

En-3 Fig. 1 Indoor Unit

1Operating Control Panel (Fig. 2)

2 MANUAL AUTO button

When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.

The forced cooling operation is used at the time of installation.

Only for authorized service personnel's use.

When the forced cooling operation starts by any chance, press the START/STOP but- ton to stop the operation.

3Indicator (Fig. 3)

4Remote Control Signal Receiver

5 OPERATION Indicator Lamp (red)

6 TIMER Indicator Lamp (green)

If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 14 Auto Restart).

7SUPER QUIET Indicator Lamp (green)

8 COIL DRY Indicator Lamp (orange)

9Intake Grille (Fig. 4)

0 Front Panel A Air Filter

B Air Flow Direction Louver C Right-Left Louver

(behind Air Flow Direction Louver) D Drain Hose

E Air Cleaning Filter

Manual background Fig. 5 Outdoor Unit

FPipe Unit

GDrain port (bottom) H Intake Port

I Outlet Port

Refer to the folded out page on the cover.

Manual background Fig. 6 Remote Control Unit Manual background

JSLEEP button

KMASTER CONTROL button L SET TEMP. button ( Manual background / Manual background ) M COIL DRY button

N Signal Transmitter O TIMER MODE button

P TIMER SET ( Manual background / Manual background ) button Q FAN CONTROL button

R START/STOP button S SET button

T SWING button U RESET button V TEST RUN button

This button is used when installing the conditioner, and should not be used un- der normal conditions, as it will cause the air conditioner’s thermostat function to op- erate incorrectly.

If this button is pressed during normal op- eration, the unit will switch to test opera- tion mode, and the Indoor Unit’s OPERA- TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.

To stop the test operation mode, press the START/STOP button to stop the air condi- tioner.

WCLOCK ADJUST button

XRemote Control Unit Display (Fig. 7) Y Transmit Indicator

Z Clock Display

[ Operating Mode Display \ Timer Mode Display ] Fan Speed Display

` Temperature SET Display a COIL DRY Display

b SLEEP Display c SWING Display

En-3