Status reporting

Error Codes summary

Error Codes summary

The following is a list of error codes generated by the Power Modules and the main controller of the XMP 2600.

Power

Modules

Errors Reported by the Power Module

1 Processor Watchdog was activated.

7Severe OCP error - output did not shut down.

8Severe OVP error - output did not shut down.

9Test error - VOUT zero test failed.

10Test error - half the full scale VOUT test failed.

11Test error - OVP circuit did not trip.

12Test error - OVP circuit did not reset.

13Output did not shut down.

14Sense lines voltage drop exceeded 4V.

15Current Limit was active following a three seconds period of the output being set to zero voltage during a Retry Foldback.

16Test error - output current was not zero during the output test.

17Internal Communication Time Out.

18Internal Communications buffer overflow.

19output voltage did not drop to zero during the reprogramming period when the relays were operated.

20Internal Communication Checksum error.

21Illegal command in the Internal Communications.

22Internal Communications Command Error.

Errors Detected by the Main Controller

 

78

Internal Communications Time Out.

 

251

Internal Communications response by the Power Module was in error.

 

Errors detected during Channels Scan at Power-On

 

240

Internal Communications Time Out - Power Module not installed.

 

241

Power Module has failed its self-test.

 

242

Internal Communications response by the Power Module was in error.

 

244

Power Module did not respond with RDY.

 

247

The Power Module reported spec data did not match the internal table.

 

Errors detected during Retain or Recall

 

248

Internal Communications Time Out - Power Module not installed.

Main

Power Modules Communications errors

Controller

1

Error during channels scan (power-on).

 

2

Power Module’s response to status query was in error.

 

3

Communications Interrupt Line is asserted and no Power Module responded to

 

 

scan.

 

4

Internal communication receive buffer was full.

XMP 2600 Programming Manual rev. 1.1

77

Page 90