Error Codes summary

Status reporting

16Internal Communications Time Out for Power Module in channel 1.

17Internal Communications Time Out for Power Module in channel 2.

18Internal Communications Time Out for Power Module in channel 3.

19Internal Communications Time Out for Power Module in channel 4.

20Internal Communications Time Out for Power Module in channel 5.

21Internal Communications Time Out for Power Module in channel 6.

22Internal Communications Time Out for Power Module in channel 7.

23Internal Communications Time Out for Power Module in channel 8.

24Internal Communications Time Out for Power Module in channel 9.

25Internal Communications Time Out for Power Module in channel 10.

26Internal Communications Time Out for Power Module in channel 11.

27Internal Communications Time Out for Power Module in channel 12.

28Internal Communications Time Out for Power Module in channel 13.

29Internal Communications Time Out for Power Module in channel 14.

30Internal Communications Time Out for Power Module in channel 15.

31Internal Communications Time Out for Power Module in channel 16.

RS232 Communications errors

32Data received while DTR was off (receive buffer is full).

33Transmit buffer is full.

34Receive Parity Error.

GPIB Communications errors

48Bus Error (reported by hardware).

49Input Queue was full so the Bus Trigger command can not be executed.

50Input Queue was full so the EOI message (set on last character which is not a LF) can not be processed.

Parser and Execution errors

37 Communications Driver error (false End Of Command).

39The Parser lost synchronization with the Input Stream (processing a non-existing command).

64a miss-placed CR in the Input Stream.

65Command or Query Mnemonics are too long (more than 6 characters).

66Illegal Command or Query (first character).

67Illegal Command or Query.

68Missing parameter (value).

69Non-digit character in Numeric Parameter..

70Parameter value overflow.

71Parameter value is less than zero (negative).

72Not a valid Channel Number (should be in the range 1 to 16).

73Parameter value is out of its allowed range.

74Can not display the string.

75The referenced Channel has no operative Power Module installed.

76The referenced Storage Area is empty - no data to recall.

77Protection settings can not be programmed (Auto Protection Mode is on).

78

XMP 2600 Programming Manual rev. 1.1

Page 91
Image 91
Xantrex Technology XMP 2600 manual RS232 Communications errors, Gpib Communications errors, Parser and Execution errors