Xantrex Technology XMP 2600 manual Commands and Queries Reference, Alphabetical reference

Models: XMP 2600

1 93
Download 93 pages 36.85 Kb
Page 70
Image 70

Commands and Queries Reference

 

Alphabetical reference

PROT

set-up the Protection Mode of the Power Module.

 

Syntax

PROT <ch>,<int>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the desired Protection Mode: a value of “0” means

 

 

Manual Protection Mode - in this mode the OVP and

 

 

OCP thresholds are programmed by the user. A

 

 

value of “1” means Automatic Protection Mode - the

 

 

OVP and OCP thresholds are set, automatically, by

 

 

the XMP 2600 as 10% to 20% above the SET

 

 

values. If changing from Manual to Automatic mode

 

 

then new OVP and OCP thresholds are calculated.

 

Category

Protection

Type: Overlapped

PROT?

return the current Protection Mode of the XMP 2600.

 

Syntax

PROT? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Protection

Type: Sequential

PSR?

return the value of the Primary Status Register. The value returned is a

 

decimal number in the range 0 to 255 representing the bits of the

 

Register.

 

 

 

Syntax

PSR?

 

 

Parameters

none

 

 

Category

Status

Type: Sequential

PWR?

return the value of the Power Warning Threshold of the XMP 2600

 

master mainframe. For the XMP 2600 this value is 2400.

 

Syntax

PWR?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

RAMP

program the Power Module’s Ramp Duration.

 

Syntax

RAMP <ch>,<ramp_duration>

 

Parameters

the number of the Power Module to be programmed.

 

 

the Ramp Duration in units of mili-seconds. The

 

 

XMP 2600 Ramp Duration resolution is 6mS, so the

 

 

programmed value will be set internally to a

 

 

multiplication of 6. The general format for the Ramp

 

 

Duration is: sss:nnn

where sss=seconds and

 

 

nnn=mili-seconds. The maximal duration is 393:210.

 

 

Duration can be programmed in units of mili-

 

 

seconds (e.g. “4032” = 004:032) or seconds (e.g.

 

 

“100:” = 140:000).

 

 

Category

Settings

Type: Sequential

XMP 2600 Programming Manual rev. 1.1

57

Page 70
Image 70
Xantrex Technology manual Commands and Queries Reference, Alphabetical reference, XMP 2600 Programming Manual rev