Xantrex Technology XMP 2600 manual Commands and Queries Reference, Alphabetical reference

Models: XMP 2600

1 93
Download 93 pages 36.85 Kb
Page 60
Image 60

Commands and Queries Reference

 

Alphabetical reference

CSTS?

return the Power Module Status Structure data. The response is six

 

decimal numbers representing the bits of the status registers. The

 

registers are presented in the following order: Channel Event Status

 

Register, Channel Warning Status Register, Channel Output Status

 

Register, Channel Fault Status Register, Channel Status Register,

 

Channel Error Code. The Channel Event Status Register is cleared and

 

<rqs> and <ist> are re-calculated.

 

 

Syntax

CSTS? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Status

Type: Sequential

DISC

program the Power Module to connect or disconnect its output relay.

 

Syntax

DISC <ch>,<int>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the desired state of the output relay: a value of “0”

 

 

will cause the relay to close and a value of “1” will

 

 

cause the relay to open.

 

 

Category

Output

Type: Overlapped

DISC?

return the state of the output relay. A value of “0” is returned for a

 

close relay and a value of “1” is returned for an open relay.

 

Syntax

DISC? <ch>

 

 

Parameters

the number of the channels to be queried.

 

Category

Output

Type: Sequential

DLY

program the

Power Module’s re-programming delay period.

 

Following a change in the output settings of a Power Module there

 

will be a period of time in which the Power Module will ignore

 

abnormal working conditions. In addition, during this re-programming

 

delay period, the Over Voltage Protection settings will, temporarily,

 

be set to maximum.

 

 

Syntax

DLY <ch>,<int>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the amount of delay expressed in seconds. The

 

 

allowed range is 0 to 25.5. The resolution used by

 

 

the Power Module is 0.1 of a second.

 

Category

Settings

Type: Sequential

DLY?

return the current re-programming delay period of the Power Module.

 

The returned value is a decimal number in the range 0 to 25.5.

 

Syntax

DLY? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Settings

Type: Sequential

XMP 2600 Programming Manual rev. 1.1