Alphabetical reference

 

Commands and Queries Reference

*TST?

initiates a self-test of the XMP 2600 main control circuits. The tested

 

areas are: Controller Internal RAM, Tables Storage RAM, Settings

 

Storage Areas and Buffers RAM. The result of the self-test is reported

 

as a decimal number in the range 0 to 16 representing the bits of the

 

result register.

 

 

 

Syntax

*TST?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

*WAI

prevent the XMP 2600 from parsing any further commands or queries

 

until all pending operations have finished.

 

 

Syntax

*WAI

 

 

Parameters

none

 

 

Category

Synchronization

Type: Sequential

ARM

program a Power Module to the Armed state in which further SET,

 

PROT and POL programming will be stored with no immediate effect

 

of the output of the Power Module.

 

 

Syntax

ARM <ch>

 

 

Parameters

the number of the channel to be armed.

 

Category

Trigger and Sync

Type: Sequential

ARM?

return the state of the Power Module. The value returned is “0” if the

 

module is not armed and “1” if it is.

 

 

Syntax

ARM? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Trigger and Sync

Type: Sequential

BUFCLR

empty the Output Queue.

 

 

Syntax

BUFCLR

 

 

Parameters

none

 

 

Category

System

Type: Sequential

CALDT?

return the Calibration Date of a Power Module. The response is an

 

unquoted string with the following format: dd/mm/yy where: dd is the

 

day of the month, mm is the month and yy is the last two digits of the

 

year.

 

 

 

Syntax

CALDT? <ch>

 

 

Parameters

the number of the Channel to be queried.

 

Category

Status

Type: Sequential

44

XMP 2600 Programming Manual rev. 1.1

Page 57
Image 57
Xantrex Technology XMP 2600 manual Result register Syntax