Alphabetical reference |
| Commands and Queries Reference | |
DSP | remove a user message from the XMP 2600 front panel display. | ||
| Syntax | DSP |
|
| Parameters | none |
|
| Category | System | Type: Sequential |
DSP | display a message on the XMP 2600 front panel display. | ||
| Syntax | DSP <string> |
|
| Parameters | the message to be displayed, limited to 21 | |
|
| characters. Extra characters are truncated. | |
| Category | System | Type: Sequential |
ERR? | return the last known Error Code of the XMP 2600 main controller. | ||
| The error code is cleared. |
| |
| Syntax | ERR? |
|
| Parameters | none |
|
| Category | Status | Type: Sequential |
ERR? | return the last know Power Module error code. The error code is | ||
| cleared. |
|
|
| Syntax | ERR? <ch> |
|
| Parameters | the number of the channel to be queried. | |
| Category | Status | Type: Sequential |
FOLD | program the type of Foldback to be used by the Power Module when | ||
| Current Limit is reached. |
| |
| Syntax | FOLD <ch>,<int> |
|
| Parameters | the number of the Power Module to be programmed. | |
|
| the type of Foldback - a decimal value in the range 0 | |
|
| to 4, as detailed below: |
|
|
| 0 = no Foldback |
|
|
| 1 = retry Foldback |
|
|
| 2 = linear Foldback |
|
|
| 3 = nonlinear Foldback |
|
|
| 4 = shutdown Foldback |
|
|
| See the “current limiting schemes” section of the | |
|
| Basic Programming chapter for details on Foldback | |
|
| behavior. |
|
| Category | Settings | Type: Overlapped |
FOLD? | return the current Foldback selection of the Power Module. | ||
| Syntax | FOLD? <ch> |
|
| Parameters | the number of the channel to be queried. | |
| Category | Settings | Type: Sequential |
48 | XMP 2600 Programming Manual rev. 1.1 |