Xantrex Technology XMP 2600 5Commands and Queries Reference, Categories, IEEE 488.1 BUS Commands

Models: XMP 2600

1 93
Download 93 pages 36.85 Kb
Page 48
Image 48
Commands and Queries Reference

Commands and Queries Reference

Categories

5Commands and Queries Reference

This chapter describes all the commands and queries available when programming the XMP 2600 from a remote controller. The chapter provides a list of Commands and Queries grouped by category and an alphabetical reference of Commands and Queries.

Categories

IEEE 488.1 BUS Commands

This part of the commands and queries reference lists all of them divided into functional categories.

Device Clear

Clear input and output queues. Abort Operation

 

Complete Hold-Off.

System

Commands

and Queries

This is the only way to remotely recover from a situation where the XMP 2600 Main Controller is holding off command parsing due to executing one of the following commands: *OPC, *OPC? and *WAI. This method is available only with GPIB.

Device Trigger ............................... Toggle Global Output Enable On / Off.

*IDN?

return a string identifying the XMP 2600.

*OPT?

return a “1” if the XMP 2600 has a Front.

*RCL

restores settings of all the Power Modules.

*RST

returns the XMP 2600 to its Power On state.

*SAV

stores settings of all the Power Modules.

*SDS

initialize the contents of a storage area.

*TST?

initiates a self-test of the XMP 2600 main control circuits.

BUFCLR

empty the Output Queue.

CHNL?

return installed Power Modules.

CLR

returns the XMP 2600 to its power on state

CONF?

initiates a self-test of the XMP 2600 main control circuits.

DSP

display or remove a message on the XMP 2600 front panel display.

XMP 2600 Programming Manual rev. 1.1

35