Commands and Queries Reference

Categories

Settings

Commands

and Queries

Output

Control

Commands

and Queries

Protection

Commands

and Queries

DLY

program the Power Module’s re-programming delay period.

DLY?

return the current re-programming delay period of the Power Module.

FOLD

program the type of Foldback to be used by the Power Module when

 

Current Limit is reached.

FOLD?

return the current Foldback selection of the Power Module.

ILIM

program an upper limit on subsequent programming of current settings

 

for the Power Module.

ILIM?

return the current value of the upper limit on ISET programming.

IMAX?

return the value of the Power Module’s output current rating.

IMIN?

return the value of the minimum programmable current limit for the

 

Power Module.

ISET

program the current limiting of the Power Module’s output.

ISET?

return the current programmed value of the Power Module’s output

 

current limit.

POLEN

enables the XMP 2600 to accept signed value parameters.

POLEN?

return the current state of the Polarity Enable Flag.

RAMP

program the Power Module’s Ramp Duration.

RAMP?

return the current Ramp Duration for the Power Module.

RIPL

program the Power Module to simulate ripple at its output.

RIPL?

return the current programmed output ripple for the Power Module.

VLIM

program an upper limit on subsequent programming of voltage settings

 

for the Power Module.

VLIM?

return the current value of the upper limit on VSET programming.

VMAX?

return the value of the Power Module’s output voltage rating.

VSET

program the voltage limiting of the Power Module’s output.

VSET?

return the current programmed value of the Power Module’s load voltage

 

limit.

DISC

program the Power Module to connect or disconnect its output relay.

DISC?

return the state of the output relay.

OUT

program the state of the Global Output Enable Flag of the XMP 2600.

OUT

program the state of the Power Module Output.

OUT?

return the current state of the Global Output Enable Flag.

OUT?

return the current state of the Power Module’s output

POL

change the Power Module’s output polarity.

POL?

return the current output polarity of the Power Module.

OCSET

program the Power Module’s Over Current Protection.

OCSET?

return the current programmed value of the Power Module’s OCP

 

threshold.

OVRST

reset OVP and OCP errors reported by the Power Module.

OVSET

program the Power Module’s Over Voltage Protection.

OVSET?

return the current programmed value of the Power Module’s OVP

 

threshold.

PROT

set-up the Protection Mode of the Power Module.

PROT?

return the current Protection Mode of the XMP 2600.

XMP 2600 Programming Manual rev. 1.1

37

Page 50
Image 50