MON

change the

operating mode of the RS232 serial communication

 

interface into or out of Monitor Mode.

 

 

Syntax

MON <int>

 

 

Parameters

the requested mode of operation for the RS232 serial

 

 

interface. A value of “0” will turn Monitor Mode

 

 

off. A value of “1” will turn it on.

 

Category

System

Type: Overlapped

MON?

return the current state of the Monitor Mode. A value of “0” means

 

that Monitor Mode is off. A value of “1” indicate that the Monitor

 

Mode is on.

 

 

 

Syntax

MON?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

OCRST

see OVRST

 

 

OCSET

program the Power Module’s Over Current Protection.

 

Syntax

OCSET <ch>,<value>

 

 

Parameters

the number of the Power Module to be programmed.

 

 

the value to be assigned to the OCP threshold. A

 

 

value can only be programmed when PROT mode is

 

 

Manual. The upper limit of the Programmed value is

 

 

IMAX + 1. The lower limit of the programmed

 

 

value is ISET.

 

 

Category

Protection

Type: Sequential

OCSET?

return the current programmed value of the Power Module’s OCP

 

threshold. The result is a <value>.

 

 

Syntax:

OCSET? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Protection

Type: Sequentail

OPT?

return the Options Byte of the Power Module. The result is a decimal

 

value in the range 0 to 255 representing bits of the Options Byte.

 

For now only three bits have meaning:

 

 

Bit 4 is cleared when the Power Module has the output

 

disconnect relay option.

 

 

Bit 5 is cleared if the Power Module has the polarity reversal

 

relay option.

 

 

Bit 3 is set if this module has power monitoring logic (e.g. 1/8wide

 

36V/40A module)

 

 

Syntax

OPT? <ch>

 

 

Parameters

the number of the channel to be queried.

 

Category

Status

Type: Sequential