Alphabetical reference

 

Commands and Queries Reference

*PRE

assign new value to the Parallel Poll Enable Register. Re-calculates

 

<ist>.

 

 

 

Syntax

*PRE <int>

 

 

Parameters

the value to be assigned to the Register - a decimal

 

 

number in the range 0 to 255 representing bits in the

 

 

Register.

 

 

Category

Status

Type: Sequential

*PRE?

return the

value of the Parallel Poll Enable Register. The value

 

returned is a decimal number in the range 0 to 255 representing the

 

bits of the Register.

 

 

Syntax

*PRE?

 

 

Parameters

none

 

 

Category

Status

Type: Sequential

*PSC

controls whether or not the XMP 2600 will clear all the Event Enable

 

Registers and the SRQ and Parallel Poll Enable Registers at Power

 

On.

 

 

 

Syntax

*PSC <int>

 

 

Parameters

a value of 0 disables the XMP 2600 from clearing

 

 

the Registers at Power On. Any other value (in the

 

 

range 1 to 255) enables clearing of the Register.

 

Category

Status

Type: Sequential

*PSC?

return the

value of the Power On Status Clear Enable Flag: “0”

 

(disabled) or “1” (enabled).

 

 

Syntax

*PSC?

 

 

Parameters

none

 

 

Category

Status

Type: Sequential

*RCL

restores settings of all the Power Modules (same as RCL command).

 

Syntax

*RCL <int>

 

 

Parameters

a decimal number in the range 0 to 9 specifying the

 

 

storage number the XMP 2600 will restore the

 

 

settings from.

 

 

Category

System

Type: Overlapped

*RST

returns the XMP 2600 to its

Power On state: send a Fault Reset

 

Command to all faulty Power Modules, if the Primary was shut down

 

then try to revive it, Initialize or Retain Power Modules Settings,

 

return the Front Panel Display to Normal Status Mode. Does not clear

 

the status structures (except for the Primary status).

 

Syntax

*RST

 

 

Parameters

none

 

 

Category

System

Type: Sequential

42

XMP 2600 Programming Manual rev. 1.1

Page 55
Image 55