Commands and Queries Reference

Alphabetical reference

TOEN?

queries the

current state of the remote

communication time out

 

feature.

 

 

 

Syntax

TOEN?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

TOGRP

defines the

group of channels to be shut-down when a remote

 

communication time out occurs.

 

 

Syntax

TOGRP <int>,<int>

 

 

Parameters

the two integers are (respectively) the high and low

 

 

parts of a 16 bits word where each bit represent a

 

 

Power Module. If the bit value is “0” then that

 

 

Power Module is not part of the group. If the bit

 

 

value is “1” then that Power Module is part of the

 

 

group of modules that will shut-down on remote

 

 

communication time out.

 

 

Category

System

Type: Sequential

Do not change the group members while a remote communication time out event is valid. Changing the group members while the event is valid will not change the state of the output of the modules being removed from or added to the group.

TOGRP?

return the current definition of the group of Power Modules that will

 

shut-down when a remote communication time out occurs. The

 

response is made up of two decimal numbers (each in the range 0 to

 

255) being the high (sent first) and low parts of a 16 bits word. Each

 

bit in the response represents the membership of a Power Module in

 

the group (see TOGRP command for details on bit values).

 

Syntax

 

TOGRP?

 

 

Parameters

none

 

 

Category

System

Type: Sequential

TORST

resets the remote communication time out event: clears the status bit

 

and performs the operation defined with the TOEN command. The

 

operation performed will be:

 

 

0

= none.

 

 

 

1

= restore output state of group (see TOGRP) members.

 

2

= none.

 

 

 

3

= stop the sequence program.

 

 

4

= recall from area 8.

 

 

5

= stop the sequence program then recall from area 8.

 

Syntax

 

TORST

 

 

Parameters

none

 

 

Category

System

Type: Overlapped

XMP 2600 Programming Manual rev. 1.1

63

Page 76
Image 76